Back to Search Start Over

Six-minute-walk test in idiopathic pulmonary fibrosis: test validation and minimal clinically important difference.

Authors :
Bois RM
Weycker D
Albera C
Bradford WZ
Costabel U
Kartashov A
Lancaster L
Noble PW
Sahn SA
Szwarcberg J
Thomeer M
Valeyre D
King TE Jr
Source :
American Journal of Respiratory & Critical Care Medicine; 5/1/2011, Vol. 183 Issue 9, p1231-1237, 7p
Publication Year :
2011

Abstract

Rationale: The 6-minute-walk test (6MWT) is a practical and clinically meaningful measure of exercise tolerance with favorable performance characteristics in various cardiac and pulmonary diseases. Performance characteristics in patients with idiopathic pulmonary fibrosis (IPF) have not been systematically evaluated. Objectives: To assess the reliability, validity, and responsiveness of the 6MWT and estimate the minimal clinically important difference (MCID) in patients with IPF. Methods: The study population included all subjects completing a 6MWT in a clinical trial evaluating interferon gamma-1b (n = 822). Six-minute walk distance (6MWD) and other parameters were measured at baseline and at 24-week intervals using a standardized protocol. Parametric and distribution-independent correlation coefficients were used to assess the strength of the relationships between 6MWD and measures of pulmonary function, dyspnea, and health-related quality of life. Both distribution-based and anchor-based methods were used to estimate the MCID. Measurements and Main Results: Comparison of two proximal measures of 6MWD (mean interval, 24 d) demonstrated good reliability (coefficient = 0.83; P < 0.001). 6MWD was weakly correlated with measures of physiologic function and health-related quality of life; however, values were consistently and significantly lower for patients with the poorest functional status, suggesting good construct validity. Importantly, change in 6MWD was highly predictive of mortality; a 24-week decline of greater than 50 m was associated with a fourfold increase in risk of death at 1 year (hazard ratio, 4.27; 95% confidence interval, 2.57- 7.10; P < 0.001). The estimated MCID was 24-45 m. Conclusions: The 6MWT is a reliable, valid, and responsive measure of disease status and a valid endpoint for clinical trials in IPF. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
1073449X
Volume :
183
Issue :
9
Database :
Complementary Index
Journal :
American Journal of Respiratory & Critical Care Medicine
Publication Type :
Academic Journal
Accession number :
104890120
Full Text :
https://doi.org/10.1164/rccm.201007-1179OC