Back to Search Start Over

Diagnostic accuracy of dual-source CT coronary angiography: The effect of average heart rate, heart rate variability, and calcium score in a clinical perspective.

Authors :
Zhang LJ
Wu SY
Wang J
Lu Y
Zhang ZL
Jiang SS
Zhou CS
Lu GM
Zhang, Long-Jiang
Wu, Sheng-Yong
Wang, Jing
Lu, Ying
Zhang, Zhuo-Li
Jiang, Shi-Sen
Zhou, Chang-Sheng
Lu, Guang-Ming
Source :
Acta Radiologica; Sep2010, Vol. 51 Issue 7, p727-740, 14p
Publication Year :
2010

Abstract

<bold>Background: </bold>Dual-source CT coronary angiography (CTCA) has been used to detect coronary artery disease; however, the factors with potential to affect its diagnostic accuracy remain to be defined. <bold>Purpose: </bold>To prospectively evaluate the accuracy of dual-source CTCA in diagnosing coronary artery stenosis according to conventional coronary angiography (CAG), and the effect of average heart rate, heart rate variability, and calcium score on the accuracy of CTCA. <bold>Material and Methods: </bold>A total of 113 patients underwent both dual-source CTCA and CAG. The results were used to evaluate the findings in dual-source CTCA to assess the accuracy in the diagnosis of > or =50% (significant stenosis) and >75% (severe stenosis) of coronary artery according to those by CAG. Patients were divided into subgroups according to their heart rate (HR), HR variability (HRV), and calcium score, and the accuracy of CTCA was further evaluated. The chi-square test was used to analyze the difference in sensitivity and specificity for the detection of > or =50% and >75% coronary stenosis among subgroups. The generalized estimation equation method was used in per-vessel analysis to adjust for within-patient correlation. <bold>Results: </bold>In all, 113 patients had 338 vessels and 1661 segments evaluated by CAG. Dual-source CTCA displayed 1527 segments (91.9%). Among them, 1468 segments (calcium score by CAG score 1, n=1018; score 2, n=270; score 3, n=180) were assessable in CTCA. On a per-patient analysis, the sensitivity and specificity of CTCA were 93.9% and 93.5% for significant stenosis and 86.9% and 98.1% for severe stenosis. On a per-vessel basis, the sensitivity and specificity were 90.2% and 97.1% for significant and 83.3% and 98.1% for severe stenosis. On a per-segment analysis, the sensitivity and specificity were 90.2% and 97.1% for significant and 83.3% and 98.1% for severe stenosis. Average HR had no effect on the sensitivity and specificity of CTCA (P>0.05); whereas HRV and calcium score had some effect on the sensitivity and specificity of CTCA (P<0.05). <bold>Conclusion: </bold>On a per-patient, per-vessel, and per-segment basis, dual-source CTCA has a high sensitivity and specificity for the diagnosis of coronary artery stenosis. Average HR has no effect on the diagnostic accuracy of CTCA, while HRV and calcium score have a statistically significant effect on the sensitivity and specificity of CTCA. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
02841851
Volume :
51
Issue :
7
Database :
Complementary Index
Journal :
Acta Radiologica
Publication Type :
Academic Journal
Accession number :
105079232
Full Text :
https://doi.org/10.3109/02841851.2010.492792