Back to Search Start Over

Exhaled air dispersion distances during noninvasive ventilation via different Respironics face masks.

Authors :
Hui DS
Chow BK
Ng SS
Chu LC
Hall SD
Gin T
Sung JJ
Chan MT
Hui, David S
Chow, Benny K
Ng, Susanna S
Chu, Leo C Y
Hall, Stephen D
Gin, Tony
Sung, Joseph J Y
Chan, Matthew T V
Source :
CHEST; 2009 Oct, Vol. 136 Issue 4, p998-1005, 8p
Publication Year :
2009

Abstract

<bold>Background: </bold>As part of our influenza pandemic preparedness, we studied the exhaled air dispersion distances and directions through two different face masks (Respironics; Murrysville, PA) attached to a human-patient simulator (HPS) during noninvasive positive-pressure ventilation (NPPV) in an isolation room with pressure of -5 Pa.<bold>Methods: </bold>The HPS was positioned at 45 degrees on the bed and programmed to mimic mild lung injury (oxygen consumption, 300 mL/min; lung compliance, 35 mL/cm H(2)O). Airflow was marked with intrapulmonary smoke for visualization. Inspiratory positive airway pressure (IPAP) started at 10 cm H(2)O and gradually increased to 18 cm H(2)O, whereas expiratory pressure was maintained at 4 cm H(2)O. A leakage jet plume was revealed by a laser light sheet, and images were captured by high definition video. Normalized exhaled air concentration in the plume was estimated from the light scattered by the smoke particles.<bold>Findings: </bold>As IPAP increased from 10 to 18 cm H(2)O, the exhaled air of a low normalized concentration through the ComfortFull 2 mask (Respironics) increased from 0.65 to 0.85 m at a direction perpendicular to the head of the HPS along the median sagittal plane. When the IPAP of 10 cm H(2)O was applied via the Image 3 mask (Respironics) connected to the whisper swivel, the exhaled air dispersed to 0.95 m toward the end of the bed along the median sagittal plane, whereas higher IPAP resulted in wider spread of a higher concentration of smoke.<bold>Conclusions: </bold>Substantial exposure to exhaled air occurs within a 1-m region, from patients receiving NPPV via the ComfortFull 2 mask and the Image 3 mask, with more diffuse leakage from the latter, especially at higher IPAP. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00123692
Volume :
136
Issue :
4
Database :
Complementary Index
Journal :
CHEST
Publication Type :
Academic Journal
Accession number :
105319678
Full Text :
https://doi.org/10.1378/chest.09-0434