Evaluation of Iron Loss of AC Filter Inductor Used in Three-Phase PWM Inverters Based on an Iron Loss Analyzer.
- Source :
- IEEE Transactions on Power Electronics; Apr2016, Vol. 31 Issue 4, p3080-3095, 16p
- Publication Year :
- 2016
-
Abstract
- The authors have proposed two methods for iron loss evaluation of the ac filter inductor used in a pulsewidth modulation (PWM) inverter. The first method is a loss map method, which can be used for the iron loss calculation of the ac filter inductor without using a real PWM inverter, and the second method is an iron loss analyzer (ILA), which can measure the iron loss of the ac filter inductor during every switching period on a real PWM inverter. In this paper, the measurement results obtained using the ILA and the results calculated using the loss map method on both the single-phase and three-phase inverters are compared. The calculated iron loss of the ac filter inductor on the three-phase PWM inverter is found to have a relatively large error for certain PWM pulse conditions. In order to reduce the calculation error, the authors propose a modified loss calculation method and demonstrate that the calculation error is reduced to less than 2%. [ABSTRACT FROM PUBLISHER]
Details
- Language :
- English
- ISSN :
- 08858993
- Volume :
- 31
- Issue :
- 4
- Database :
- Complementary Index
- Journal :
- IEEE Transactions on Power Electronics
- Publication Type :
- Academic Journal
- Accession number :
- 111308915
- Full Text :
- https://doi.org/10.1109/TPEL.2015.2453055