Influence analysis of monolith structure on regeneration temperature in the process of microwave regeneration in the diesel particulate filter.

Authors :
E, Jiaqiang
Liu, Ming
Deng, Yuanwang
Zhu, Hao
Gong, Jinke
Source :
Canadian Journal of Chemical Engineering; Jan2016, Vol. 94 Issue 1, p168-174, 7p
Publication Year :
2016

Abstract

Based on models A, B, and C of three kinds of diesel particulate filter (DPF) with microwave regeneration, a DPF microwave regeneration model is established according to the laws of conservation of mass, momentum, and energy. The trends of internal temperature under different velocities of exhaust gas in channels are simulated and analyzed. The results show that: (1) Regeneration temperature in the process of microwave regeneration will begin to increase from the front to the rear end of along the axial direction, and the maximum temperature value will appear in the rear end of the monolith. (2) The internal flow velocity in the DPF of model C is the most uniform and the temperature gradient is the smallest among the three models. Therefore, it is the most useful for DPF regeneration. (3) The minimal thermal stress is exerted on the DPF of model C. Therefore, this model is most useful for prolonging the service life of a DPF. [ABSTRACT FROM AUTHOR]