Back to Search Start Over

EURADOS-IDEAS GUIDELINES (VERSION 2) FOR THE ESTIMATION OF COMMITTED DOSES FROM INCORPORATION MONITORING DATA.

Authors :
Castellani, C. M.
Marsh, J. W.
Hurtgen, C.
Blanchardon, E.
Bérard, P.
Giussani, A.
Lopez, M. A.
Source :
Radiation Protection Dosimetry; Sep2016, Vol. 170 Issue 1-4, p17-20, 4p
Publication Year :
2016

Abstract

Dose assessment after intakes of radionuclides requires application of biokinetic and dosimetric models and assumptions about factors influencing the final result. In 2006, a document giving guidance for such assessment was published, commonly referred to as the IDEAS Guidelines. Following its publication, a working group within the European networks CONRAD and EURADOS was established to improve and update the IDEAS Guidelines. This work resulted in Version 2 of the IDEAS Guidelines, which was published in 2013 in the form of a EURADOS report. The general structure of the original document was maintained; however, new procedures were included, e.g. the direct dose assessment method for <superscript>3</superscript>H or special procedure for wound cases applying the NCRP wound model. In addition, information was updated and expanded, e.g. data on dietary excretion of U, Th, Ra and Po for urine and faeces or typical and achievable values for detection limits for different bioassay measurement techniques. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01448420
Volume :
170
Issue :
1-4
Database :
Complementary Index
Journal :
Radiation Protection Dosimetry
Publication Type :
Academic Journal
Accession number :
117975279
Full Text :
https://doi.org/10.1093/rpd/ncv457