Back to Search Start Over

Direct comparison of 129 Xe diffusion measurements with quantitative histology in human lungs.

Authors :
Thomen, Robert P.
Quirk, James D.
Roach, David
Egan‐Rojas, Tiffany
Ruppert, Kai
Yusen, Roger D.
Altes, Talissa A.
Yablonskiy, Dmitriy A.
Woods, Jason C.
Source :
Magnetic Resonance in Medicine; Jan2017, Vol. 77 Issue 1, p265-272, 8p
Publication Year :
2017

Abstract

Purpose Chronic obstructive pulmonary disease (COPD) is an irreversible lung disease characterized by small-airway obstruction and alveolar-airspace destruction. Hyperpolarized <superscript>129</superscript>Xe diffusion MRI of lung is a promising biomarker for assessing airspace enlargement, but has yet to be validated by direct comparison to lung histology. Here we have compared diffusion measurements of hyperpolarized (HP) <superscript>129</superscript>Xe in explanted lungs to regionally matched morphological measures of airspace size. Methods Explanted lungs from five COPD patients and two idiopathic pulmonary fibrosis (IPF) patients were imaged using MRI with hyperpolarized <superscript>129</superscript>Xe using a two-b-value gradient-echo diffusion sequence, and 34 histological samples were taken from these lungs for quantitative histology. Mean-linear-intercept (L<subscript>m</subscript>) was compared with spatially matched measures of apparent diffusion coefficient (ADC) from <superscript>129</superscript>Xe MRI. Results The mean ADC from COPD lung samples was 0.071 ± 0.011 cm<superscript>2</superscript>/s, and for IPF lungs was 0.033 ± 0.001 cm<superscript>2</superscript>/s ( P < 10<superscript>−15</superscript> between groups). The mean L<subscript>m</subscript> in COPD samples was 0.076 ± 0.027 cm and 0.041 ± 0.004 cm in IPF ( P = 2.7 × 10<superscript>−7</superscript> between groups). The Pearson-correlation between ADC and L<subscript>m</subscript> measurements was r = 0.59. Conclusions Diffusion MRI of HP <superscript>129</superscript>Xe quantifies regional airspace enlargement in COPD. <superscript>129</superscript>Xe ADC showed much less overlap between groups than quantitative histology, consistent with our past experience with <superscript>3</superscript>He diffusion MRI in COPD. Magn Reson Med 77:265-272, 2017. © 2016 Wiley Periodicals, Inc. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
07403194
Volume :
77
Issue :
1
Database :
Complementary Index
Journal :
Magnetic Resonance in Medicine
Publication Type :
Academic Journal
Accession number :
120386751
Full Text :
https://doi.org/10.1002/mrm.26120