Back to Search
Start Over
The diagnostic value of 11C-methionine PET in hyperparathyroidism with negative 99mTc-MIBI SPECT: a meta-analysis.
- Source :
- Acta Radiologica; May2017, Vol. 58 Issue 5, p558-564, 7p
- Publication Year :
- 2017
-
Abstract
- Background 99mTc-sestamibi (MIBI) parathyroid SPECT is generally regarded as the best preoperative localizing method in patients with hyperparathyroidism (HPT). However, 99mTc-MIBI SPECT is false negative in approximately 25% of adenomas. 11C-methionine positron emission tomography (PET) has been used in HPT with negative 99mTc-MIBI SPECT scan results. Purpose To systematically review and conduct a meta-analysis of published data on the performance of 11C-methionine PET in patients with HPT with negative 99mTc-MIBI SPECT. Material and Methods A comprehensive review of the literature was performed. Pooled sensitivity and specificity of 11C-methionine PET in patients with HPT and a negative 99mTc-MIBI SPECT was calculated on a per-patient basis using receiver-operating characteristic (ROC) methodology. Results Nine studies that met all inclusion and exclusion criteria were included into our meta-analysis, comprising a total sample size of 137 patients. Pooled sensitivity and specificity of 11C-methionine PET in patients with HPT with negative or inconclusive 99mTc-MIBI SPECT scans was 86% and 86%, respectively. The area under the ROC curve was 0.87. Conclusion By merit of the high overall sensitivity, specificity, and accuracy, 11C-methionine PET can potentially complement the diagnostic workup of patients with HPT and negative or inconclusive 99mTc-MIBI SPECT. 11C-methionine PET appears to be a promising diagnostic modality in complicated cases with HPT. [ABSTRACT FROM AUTHOR]
- Subjects :
- METHIONINE
SINGLE-photon emission computed tomography
HYPERPARATHYROIDISM
PARATHYROID hormone
QUALITY of life
PATIENTS
COMPARATIVE studies
RESEARCH methodology
MEDICAL cooperation
META-analysis
ORGANIC compounds
PARATHYROID glands
RADIOISOTOPES
RADIOPHARMACEUTICALS
RESEARCH
RESEARCH evaluation
POSITRON emission tomography
EVALUATION research
Subjects
Details
- Language :
- English
- ISSN :
- 02841851
- Volume :
- 58
- Issue :
- 5
- Database :
- Complementary Index
- Journal :
- Acta Radiologica
- Publication Type :
- Academic Journal
- Accession number :
- 121748117
- Full Text :
- https://doi.org/10.1177/0284185116661878