Back to Search Start Over

Cone-beam CT reconstruction for non-periodic organ motion using time-ordered chain graph model.

Authors :
Masahiro Nakano
Akihiro Haga
Jun'ichi Kotoku
Taiki Magome
Yoshitaka Masutani
Shouhei Hanaoka
Satoshi Kida
Keiichi Nakagawa
Nakano, Masahiro
Haga, Akihiro
Kotoku, Jun'ichi
Magome, Taiki
Masutani, Yoshitaka
Hanaoka, Shouhei
Kida, Satoshi
Nakagawa, Keiichi
Source :
Radiation Oncology; 9/4/2017, Vol. 12, p1-14, 14p
Publication Year :
2017

Abstract

<bold>Purpose: </bold>The purpose of this study is to introduce the new concept of a four-dimensional (4D) cone-beam computed tomography (CBCT) reconstruction approach for non-periodic organ motion in cooperation with the time-ordered chain graph model (TCGM) and to compare it with previously developed methods such as total variation-based compressed sensing (TVCS) and prior-image constrained compressed sensing (PICCS).<bold>Materials and Methods: </bold>Our proposed reconstruction is based on a model including the constraint originating from the images of neighboring time phases. Namely, the reconstructed time-series images depend on each other in this TCGM scheme, and the time-ordered images are concurrently reconstructed in the iterative reconstruction approach. In this study, iterative reconstruction with the TCGM was carried out with 90° projection ranges. The images reconstructed by the TCGM were compared with the images reconstructed by TVCS (200° projection ranges) and PICCS (90° projection ranges). Two kinds of projection data sets-an elliptic-cylindrical digital phantom and two clinical patients' data-were used. For the digital phantom, an air sphere was contained and virtually moved along the longitudinal axis by 3 cm/30 s and 3 cm/60 s; the temporal resolution was evaluated by measuring the penumbral width of the air sphere. The clinical feasibility of the non-periodic time-ordered 4D CBCT image reconstruction was examined with the patient data in the pelvic region.<bold>Results: </bold>In the evaluation of the digital-phantom reconstruction, the penumbral widths of the TCGM yielded the narrowest result; the results obtained by PICCS and TCGM using 90° projection ranges were 2.8% and 18.2% for 3 cm/30 s, and 5.0% and 23.1% for 3 cm/60 s narrower than that of TVCS using 200° projection ranges. This suggests that the TCGM has a better temporal resolution, whereas PICCS seems similar to TVCS. These reconstruction methods were also compared using patients' projection data sets. Although all three reconstruction results showed motion related to rectal gas or stool, the result obtained by the TCGM was visibly clearer with less blurring.<bold>Conclusion: </bold>The TCGM is a feasible approach to visualize non-periodic organ motion. The digital-phantom results demonstrated that the proposed method provides 4D image series with a better temporal resolution compared to TVCS and PICCS. The clinical patients' results also showed that the present method enables us to visualize motion related to rectal gas and flatus in the rectum. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
1748717X
Volume :
12
Database :
Complementary Index
Journal :
Radiation Oncology
Publication Type :
Academic Journal
Accession number :
124977513
Full Text :
https://doi.org/10.1186/s13014-017-0879-8