Back to Search Start Over

Engineering design and primary experiment study of a 2.6-MV field-distortion oil switch.

Authors :
Hu, Yixiang
Wei, Hao
Qiu, Ai'ci
Zeng, Jiangtao
Sun, Fengju
Cong, Peitian
Zhang, Xinjun
Yao, Weibo
Yang, Shi
Source :
IEEE Transactions on Dielectrics & Electrical Insulation; Aug2017, Vol. 24 Issue 4, p1978-1984, 7p
Publication Year :
2017

Abstract

A 2.6-MV field-distortion oil switch was developed and tested. Engineering design theories of this switch, including electrode areas, oil anode-cathode (A-K) gaps, insulator-surface electric field, and A-K gaps of the pre-gas switch, were described in detail. Structure designs of the switch were presented. Electric-field distributions of the oil A-K gap and insulator surface were analyzed and discussed. Also, switch breakdown processes were estimated. Finally, performances of this switch were tested on the ?JianGuang-I? facility (2.3MV/350ns). Preliminary experiment results show that with a 250kV trigger voltage, the switch-breakdown time delay is about 132ns and its jitter (the standard deviation) is less than 4.4ns. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10709878
Volume :
24
Issue :
4
Database :
Complementary Index
Journal :
IEEE Transactions on Dielectrics & Electrical Insulation
Publication Type :
Academic Journal
Accession number :
125207079
Full Text :
https://doi.org/10.1109/TDEI.2016.006121