Back to Search Start Over

Design procedure of a 14.4 kV, 100 kHz transformer with a high isolation voltage (115 kV).

Authors :
Jaritz, Michael
Blume, Sebastian
Biela, Jurgen
Source :
IEEE Transactions on Dielectrics & Electrical Insulation; Aug2017, Vol. 24 Issue 4, p2094-2104, 11p
Publication Year :
2017

Abstract

In this paper, the design procedure of a 14.4 kV output voltage, 100 kHz transformer with an isolation voltage of 115 kV using Litz wire is presented. All design models, including a generalized magnetic model for the leakage and the loss calculations as well as an electrical model for the parasitic capacitance estimation for the transformer are derived and proven by measurements. For designing the insulation, a comprehensive design method based on an analytical maximum electrical field evaluation and an electrical field conform design is used. The resulting design is verified by long and short term partial discharge measurements on a prototype transformer. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10709878
Volume :
24
Issue :
4
Database :
Complementary Index
Journal :
IEEE Transactions on Dielectrics & Electrical Insulation
Publication Type :
Academic Journal
Accession number :
125207093
Full Text :
https://doi.org/10.1109/TDEI.2017.006279