Abstract

In this paper, the investigation is focused on the iron loss prediction for electrical machines fed by low switching frequency inverter. An improved iron loss model is developed after reviewing various existing iron loss models considering pulse-width modulation (PWM) influence. In order to validate the improved iron loss model, iron loss tests are carried out on an electrical machine. The predicted iron loss results match well with the measured results, which shows that the improved iron loss model is able to predict iron loss in electrical machine fed by an inverter. The comparison between the predicted iron losses with and without considering the PWM influence shows that the iron loss can be significantly increased due to the influence of PWM, especially when the switching frequency is low. [ABSTRACT FROM AUTHOR]