Postfault Operation of a Nine-Phase Six-Terminal Induction Machine Under Single Open-Line Fault.

Authors :
Abdel-Khalik, Ayman Samy
Hamad, Mostafa S.
Massoud, Ahmed M.
Ahmed, Shehab
Source :
IEEE Transactions on Industrial Electronics; Feb2018, Vol. 65 Issue 2, p1084-1096, 13p
Publication Year :
2018

Abstract

This paper studies the postfault control of a nine-phase six-terminal induction machine (IM) during single open-line fault, which was recently proposed for high-power medium-voltage applications as a promising alternative to conventional six-phase IMs. The required optimal reference currents to provide prefault loading conditions under one-line open are derived using the two most common optimization criteria employed in multiphase drives, namely, maximum torque and minimum loss modes. A postfault controller, based on conventional decoupling Clarke's transformation, is then used to ensure the same controller structure under all conditions. Consequently, the machine characteristic curves, achievable torque, and stator copper losses under these different modes are compared. A comparison with a conventional asymmetrical six-phase winding is also given. A 1.5-Hp prototype IM is used for experimental verification. [ABSTRACT FROM PUBLISHER]