Back to Search
Start Over
Results from the 4th WMO Filter Radiometer Comparison for aerosol optical depth measurements.
- Source :
- Atmospheric Chemistry & Physics Discussions; 2017, p1-27, 27p
- Publication Year :
- 2017
-
Abstract
- This study presents the results of the 4<superscript>th</superscript> Filter Radiometer Comparison that was held in Davos, Switzerland, between September 28 and October 16, 2015. Thirty filter radiometers and spectroradiometers from 12 countries participated including reference instruments from global aerosol networks. The absolute differences of all instruments compared to the reference have been based on the WMO criterion defined as "95% of the measured data has to be within 0.005±0.001/m" (where m is the air mass). At least 24 out of 29 instruments achieved this goal at both 500 and 865nm, while 12 out of 17 and 13 out of 21 achieved this at 368 and 412nm, respectively. While searching for sources of differences among different instruments, it was found that all individual differences linked to Rayleigh, NO<subscript>2</subscript>, ozone, water vapor calculations and related optical depths and air mass calculations were smaller than 0.01 in AOD at 500 and 865nm. Different cloud detecting algorithms used have been compared. Ångström exponent calculations showed relatively large differences among different instruments partly because of the sensitivity of this parameter at low AOD conditions. The overall low deviations of these AOD results and the high accuracy of reference aerosol network instruments demonstrated a promising framework to achieve homogeneity, compatibility and harmonization among the different spectral AOD networks in the near-future. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 16807367
- Database :
- Complementary Index
- Journal :
- Atmospheric Chemistry & Physics Discussions
- Publication Type :
- Academic Journal
- Accession number :
- 127070779
- Full Text :
- https://doi.org/10.5194/acp-2017-1105