Diagnostic accuracy of a pocket screening spirometer in diagnosing chronic obstructive pulmonary disease in general practice: a cross sectional validation study using tertiary care as a reference.
- Source :
- BMC Family Practice; 8/19/2016, Vol. 17, p1-11, 11p, 2 Diagrams, 4 Charts, 2 Graphs
- Publication Year :
- 2016
-
Abstract
- Background: COPD-6™ is a lung function testing device for a rapid pre-spirometry testing to screen-out at-risk individuals not having COPD and indicating those at risk. The aim of this study was to validate COPD-6™ lung function testing (index test) in general practice in discriminating patients with COPD out of the population at risk - smokers/exsmokers with no previous diagnosis of COPD, using measurements at tertiary care as reference standard. Methods: Consecutive 227 subjects (115 women, 185 smokers/42 ex-smokers, ≥20 pack-years) with no previous diagnosis of COPD, aged 52.5 (SD 6.8) years from 26 general practitioners (GPs) were recruited, lung function tested with COPD-6™, referred to the tertiary institution for repeated COPD-6™ testing followed by spirometry with a bronchodilator (salbutamol), examination, and pulmonologist consultation for the diagnosis and severity of COPD. Results: COPD was diagnosed in 43 subjects (18.9 %), with an AUC of 0.827 (95 % CI 0.769-0.875, P < 0.001) for the diagnosis of COPD when lung function was measured using COPD-6™ in GP’s office with a specificity of 100 % (95 % CI, 97.95–100 %) but a very low sensitivity of 32.56 % (95 % CI, 20.49–47.48 %). Significant agreement for forced expiratory volume in 1 s measured at GP’s office and at lung function lab was found (mean difference 0.01 L, p = 0.667) but not for other measured parameters (p < 0.001 for all). Conclusions: Our study results point out that active case finding in a population at risk for COPD should be instituted (almost 20 % of undiagnosed COPD). Based on our results lung function testing with COPD-6™ can substitute spirometry testing in cases where it is not readily available to the patient/physician taken into account that the traditional FEV1/FEV6 cutoff value of <0.7 is not the only criterion for diagnosis and/or further referral. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 14712296
- Volume :
- 17
- Database :
- Complementary Index
- Journal :
- BMC Family Practice
- Publication Type :
- Academic Journal
- Accession number :
- 127516901
- Full Text :
- https://doi.org/10.1186/s12875-016-0518-8