Back to Search Start Over

Japanese multicenter database of healthy controls for [123I]FP-CIT SPECT.

Authors :
Matsuda, Hiroshi
Murata, Miho
Mukai, Yohei
Sako, Kazuya
Ono, Hidetoshi
Toyama, Hiroshi
Inui, Yoshitaka
Taki, Yasuyuki
Shimomura, Hideo
Nagayama, Hiroshi
Tateno, Amane
Ono, Kenjiro
Murakami, Hidetomo
Kono, Atsushi
Hirano, Shigeki
Kuwabara, Satoshi
Maikusa, Norihide
Ogawa, Masayo
Imabayashi, Etsuko
Sato, Noriko
Source :
European Journal of Nuclear Medicine & Molecular Imaging; Jul2018, Vol. 45 Issue 8, p1405-1416, 12p, 5 Charts, 7 Graphs
Publication Year :
2018

Abstract

Purpose: The aim of this multicenter trial was to generate a [<superscript>123</superscript>I]FP-CIT SPECT database of healthy controls from the common SPECT systems available in Japan.Methods: This study included 510 sets of SPECT data from 256 healthy controls (116 men and 140 women; age range, 30-83 years) acquired from eight different centers. Images were reconstructed without attenuation or scatter correction (NOACNOSC), with only attenuation correction using the Chang method (ChangACNOSC) or X-ray CT (CTACNOSC), and with both scatter and attenuation correction using the Chang method (ChangACSC) or X-ray CT (CTACSC). These SPECT images were analyzed using the Southampton method. The outcome measure was the specific binding ratio (SBR) in the striatum. These striatal SBRs were calibrated from prior experiments using a striatal phantom.Results: The original SBRs gradually decreased in the order of ChangACSC, CTACSC, ChangACNOSC, CTACNOSC, and NOACNOSC. The SBRs for NOACNOSC were 46% lower than those for ChangACSC. In contrast, the calibrated SBRs were almost equal under no scatter correction (NOSC) conditions. A significant effect of age was found, with an SBR decline rate of 6.3% per decade. In the 30-39 age group, SBRs were 12.2% higher in women than in men, but this increase declined with age and was absent in the 70-79 age group.Conclusions: This study provided a large-scale quantitative database of [<superscript>123</superscript>I]FP-CIT SPECT scans from different scanners in healthy controls across a wide age range and with balanced sex representation. The phantom calibration effectively harmonizes SPECT data from different SPECT systems under NOSC conditions. The data collected in this study may serve as a reference database. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
16197070
Volume :
45
Issue :
8
Database :
Complementary Index
Journal :
European Journal of Nuclear Medicine & Molecular Imaging
Publication Type :
Academic Journal
Accession number :
130103692
Full Text :
https://doi.org/10.1007/s00259-018-3976-5