Back to Search
Start Over
Improved sensitivity and limit-of-detection using a receive-only coil in magnetic particle imaging.
- Source :
- Physics in Medicine & Biology; Jul2018, Vol. 63 Issue 13, p1-1, 1p
- Publication Year :
- 2018
-
Abstract
- Magnetic particle imaging (MPI) is an imaging modality capable of quantitatively determining the 3D distribution of a magnetic nanoparticle (MNP) ensemble. In this work, we present a method for reducing the MNP limit of detection by employing a new receive-only coil (Rx-coil) for signal acquisition. The new signal detector is designed to improve the sensitivity and thus quality of reconstructed images. We present characterization measurements conducted with the prototype Rx-coil installed in a preclinical MPI scanner. The gradiometric design of the Rx-coil attenuates the unwanted signal contributions arising from the excitation field, leading to a 17 dB lower background level compared to the conventional dual-purpose coil (TxRx-coil), which is crucial for detecting low amounts of MNP. Network analyzer measurements of the frequency-dependent coil sensitivity, as well as spectral analysis of recorded MPI data demonstrate an overall increase of the coil sensitivity of about +12 dB for the Rx-coil. Comparisons of the sensitivity distributions revealed no significant degradations in terms of homogeneity for the Rx-coil compared to the TxRx-coil in an imaging volume of 6 × 3 × 3 cm<superscript>3</superscript>. Finally, the limit of detection was determined experimentally for each coil type using a serial dilution of MNPs, resulting in values of 133 ng of iron for the conventional TxRx-coil and 20 ng for the new Rx-coil, using an acquisition time of 2 s. A linear relationship between the reconstructed signal intensities and the iron mass in the samples was observed with coefficients of determination (R<superscript>2</superscript>) of above 99% in the range of the limit of detection to 3 10<superscript>3</superscript>ng(Fe). These results open the way for improved image quality and faster acquisition time in pre-clinical MPI scanners. [ABSTRACT FROM AUTHOR]
- Subjects :
- MAGNETIC particle imaging
MAGNETIC nanoparticles
DETECTION limit
Subjects
Details
- Language :
- English
- ISSN :
- 00319155
- Volume :
- 63
- Issue :
- 13
- Database :
- Complementary Index
- Journal :
- Physics in Medicine & Biology
- Publication Type :
- Academic Journal
- Accession number :
- 130506812
- Full Text :
- https://doi.org/10.1088/1361-6560/aacb87