Back to Search Start Over

Diurnal variation in repeated sprint performance cannot be offset when rectal and muscle temperatures are at optimal levels (38.5°C).

Authors :
Pullinger, Samuel A.
Oksa, Juha
Clark, Liam F.
Guyatt, Joe W.F.
Newlove, Antonia
Burniston, Jatin G.
Doran, Dominic A.
Waterhouse, James M.
Edwards, Ben J.
Source :
Chronobiology International: The Journal of Biological & Medical Rhythm Research; Aug2018, Vol. 35 Issue 8, p1054-1065, 12p, 1 Diagram, 1 Chart, 2 Graphs
Publication Year :
2018

Abstract

The present study investigated whether increasing morning rectal temperatures (T<subscript>rec</subscript>) to evening levels, or increasing morning and evening T<subscript>rec</subscript> to an “optimal” level (38.5°C), resulting in increased muscle temperatures (T<subscript>m</subscript>), would offset diurnal variation in repeated sprint (RS) performance in a causal manner. Twelve trained males underwent five sessions [age (mean ± SD) 21.0 ± 2.3 years, maximal oxygen consumption (V̇O<subscript>2</subscript>max) 60.0 ± 4.4 mL.kg<superscript>-1</superscript> min<superscript>-1</superscript>, height 1.79 ± 0.06 m, body mass 78.2 ± 11.8 kg]. These included control morning (M, 07:30 h) and evening (E, 17:30 h) sessions (5-min warm-up), and three further sessions consisting of a warm-up morning trial (M<subscript>E</subscript>, in 39-40°C water) until T<subscript>rec</subscript> reached evening levels; two “optimal” trials in the morning and evening (M<subscript>38.5</subscript> and E<subscript>38.5</subscript>, in 39-40°C water) respectively, until T<subscript>rec</subscript> reached 38.5°C. All sessions included 3 × 3-s task-specific warm-up sprints, thereafter 10 × 3-s RS with 30-s recoveries were performed a non-motorised treadmill. T<subscript>rec</subscript> and T<subscript>m</subscript> measurements were taken at the start of the protocol and following the warm-up periods. Values for T<subscript>rec</subscript> and T<subscript>m</subscript> at rest were higher in the evening compared to morning values (0.48°C and 0.69°C, p < 0.0005). RS performance was lower (7.8-8.3%) in the M for distance covered (DC; p = 0.002), average power (AP; p = 0.029) and average velocity (AV; p = 0.002). Increasing T<subscript>rec</subscript> in the morning to evening values or optimal values (38.5°C) did not increase RS performance to evening levels (p = 1.000). However, increasing T<subscript>rec</subscript> in the evening to “optimal” level through a passive warm-up significantly reduced DC (p = 0.008), AP (p < 0.0005) and AV (p = 0.007) to values found in the M condition (6.0-6.9%). Diurnal variation in T<subscript>rec</subscript> and T<subscript>m</subscript> is not wholly accountable for time-of-day oscillations in RS performance on a non-motorised treadmill; the exact mechanism(s) for a causal link between central temperature and human performance are still unclear and require more research. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
07420528
Volume :
35
Issue :
8
Database :
Complementary Index
Journal :
Chronobiology International: The Journal of Biological & Medical Rhythm Research
Publication Type :
Academic Journal
Accession number :
132001171
Full Text :
https://doi.org/10.1080/07420528.2018.1454938