Aquadest Production System as Steam Turbine Bottom Cycle III: Influence of Wastewater Percentage and Pinch Point Temperature Difference of Condenser.
- Source :
- AIP Conference Proceedings; 2019, Vol. 2062 Issue 1, p020001-1-020001-10, 10p
- Publication Year :
- 2019
-
Abstract
- The needs for clean and safe water are growing as the population growing as well. This paper describes the variation of Wastewater Percentage and Pinch Point Temperature Difference (PPTD) on a 50 MW Steam Power Plant. After using the cooling water, not all water is discharged back to the sea, some of the water are used in throttling process where some of water will be vapor, and the other are merged with the water from water treatment and are going to be used for cooling cycle. It’s found that by decreasing the condenser pressure from 8.45 kPa to 6.45 kPa it will produce vapor that could be condense into Aquadest with SEC (Specific Energy Consumption) at best condition as much as 697.85 kJ for producing 1 kg of Aquadest on PPTD 4.3 °C. On that condition, Aquadest could be produced at 0.0178 kg/s rate and the efficiency of turbine increase about 0.16%. Another benefit of this system is that this system discharges cooler water from the process, and has less impact to the environment. [ABSTRACT FROM AUTHOR]