Back to Search Start Over

Characterization of the indoor particles and their sources in an Antarctic research station.

Authors :
Coelho Pagel, Érica
Costa Reis Jr., Neyval
Engel de Alvarez, Cristina
Santos, Jane Méri
Conti, Melina Moreira
Boldrini, Ricardo Salvador
Sansigolo Kerr, Américo
Source :
Environmental Monitoring & Assessment; Mar2016, Vol. 188 Issue 3, p1-16, 16p, 1 Black and White Photograph, 1 Diagram, 1 Chart, 7 Graphs
Publication Year :
2016

Abstract

Many studies have been carried out on the environmental impact of the research stations on the Antarctic continent. However, the assessment of indoor air quality in these confined environments has been neglected. The main objectives of this study are to investigate the granulometric distribution of the indoor particles in the different compartments of the Brazilian Antarctic Station, to examine the number and mass concentration of the indoor particles, to conduct chemical and morphological analyses of the indoor PM<subscript>2.5</subscript>, and to identify the possible sources of the PM. The results showed that Na, K, Cl, Fe, Zn, S and Si were the main elements detected. High levels of black carbon were recorded in the workshop, which may be associated with the use of diesel vehicles. To identify the human activities related to the indoor particle emission in the station, the size distribution of the particles in the living room was monitored for seven consecutive days, during normal station operation. It was possible to identify the influence of individual processes, such as incineration, cooking and the movement of people, upon the particle size number concentration. The indoor/outdoor (I/O) ratio for the total suspended particles (TSP), PM<subscript>10</subscript>, PM<subscript>2.5</subscript> and PM<subscript>1</subscript> measured was significantly larger than those reported for urban buildings. In general, the I/O ratio distribution for all the compartments shows peak values between 2.5 and 10 μm, which is often related to human activity, such as cleaning, personnel circulation or clothing surfaces. The maximum I/O ratio at this range varied from 12 to 60. In addition, the compartments affected by combustion processes tend to present a significant number of submicron particles. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01676369
Volume :
188
Issue :
3
Database :
Complementary Index
Journal :
Environmental Monitoring & Assessment
Publication Type :
Academic Journal
Accession number :
134603726
Full Text :
https://doi.org/10.1007/s10661-016-5172-z