Back to Search Start Over

An index-based method for evaluating seismic retrofitting techniques. Application to a reinforced concrete primary school in Huelva.

Authors :
Requena-García-Cruz, María-Victoria
Morales-Esteban, Antonio
Durand-Neyra, Percy
Estêvão, João M. C.
Source :
PLoS ONE; 4/10/2019, Vol. 14 Issue 4, p1-17, 17p
Publication Year :
2019

Abstract

A project named PERSISTAH (Projetos de Escolas Resilientes aos SISmos no Território do Algarve e de Huelva, in Portuguese) is being developed. It aims to cooperatively assess and improve the seismic vulnerability of primary schools in the Algarve (Portugal) and Huelva (Spain). A large number of schools have to be analysed. In order to determine which seismic retrofitting technique is optimal, an index-based method is presented in this paper. It considers three parameters: first, the efficiency of the seismic retrofitting technique in relation to the structural improvement obtained; second, the cost of the implementation of the retrofitting technique; and third, the architectural impact. It should be mentioned that a specific measurement for each solution according to its geometry has been performed. Also, coefficients to consider the singularities of each analysis and the importance of the parameters (number of buildings, typology, available funds, etc.) in the study are considered. The most representative primary school of Huelva has been chosen to test the index-based method. The most suitable retrofitting techniques for this type of buildings have been tested. The retrofitting technique which most increased the seismic performance has been the addition of X and V bracings within the building’s bays. Furthermore, the analyses have revealed that adding the retrofitting elements in the most vulnerable direction of the building provides a high efficiency. The results have also shown that implementing techniques of lower architectural impact gives acceptable results. The analysis of the mean damage level index has shown that the building would experiment a severe damage. All the retrofitting techniques applied have reduced it, at least, up to moderate damage. Finally, it should be noted that the position of the retrofitting elements is also paramount for providing an optimal retrofitting. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
19326203
Volume :
14
Issue :
4
Database :
Complementary Index
Journal :
PLoS ONE
Publication Type :
Academic Journal
Accession number :
135816684
Full Text :
https://doi.org/10.1371/journal.pone.0215120