Back to Search Start Over

Poor Concordance between Sequential Transbronchial Lung Cryobiopsy and Surgical Lung Biopsy in the Diagnosis of Diffuse Interstitial Lung Diseases.

Authors :
Romagnoli, Micaela
Colby, Thomas V
Berthet, Jean-Philippe
Gamez, Anne Sophie
Mallet, Jean-Pierre
Serre, Isabelle
Cancellieri, Alessandra
Cavazza, Alberto
Solovei, Laurence
Dell'Amore, Andrea
Dolci, Giampiero
Guerrieri, Aldo
Reynaud, Paul
Bommart, Sébastien
Zompatori, Maurizio
Dalpiaz, Giorgia
Nava, Stefano
Trisolini, Rocco
Suehs, Carey M
Vachier, Isabelle
Source :
American Journal of Respiratory & Critical Care Medicine; 5/15/2019, Vol. 199 Issue 10, p1249-1256, 8p
Publication Year :
2019

Abstract

Rationale: The diagnostic concordance between transbronchial lung cryobiopsy (TBLC)-versus surgical lung biopsy (SLB) as the current gold standard-in interstitial lung disease (ILD) cases requiring histology remains controversial. Objectives: To assess diagnostic concordance between TBLC and SLB sequentially performed in the same patients, the diagnostic yield of both techniques, and subsequent changes in multidisciplinary assessment (MDA) decisions. Methods: A two-center prospective study included patients with ILD with a nondefinite usual interstitial pneumonia pattern (on high-resolution computed tomography scan) confirmed at a first MDA. Patients underwent TBLC immediately followed by video-assisted thoracoscopy for SLB at the same anatomical locations. After open reading of both sample types by local pathologists and final diagnosis at a second MDA (MDA2), anonymized TBLC and SLB slides were blindly assessed by an external expert pathologist (T.V.C.). Kappa-concordance coefficients and percentage agreement were computed for: TBLC versus SLB, MDA2 versus TBLC, MDA2 versus SLB, and blinded pathology versus routine pathology. Measurements and Main Results: Twenty-one patients were included. The median TBLC biopsy size (longest axis) was 7 mm (interquartile range, 5-8 mm). SLB biopsy sizes averaged 46.1 ± 13.8 mm. Concordance coefficients and percentage agreement were: TBLC versus SLB: κ = 0.22 (95% confidence interval [CI], 0.01-0.44), percentage agreement = 38% (95% CI, 18-62%); MDA2 versus TBLC: κ = 0.31 (95% CI, 0.06-0.56), percentage agreement = 48% (95% CI, 26-70)%; MDA2 versus SLB: κ = 0.51 (95% CI, 0.27-0.75), percentage agreement = 62% (95% CI, 38-82%); two pneumothoraces (9.5%) were recorded during TBLC. TBLC would have led to a different treatment if SLB was not performed in 11 of 21 (52%) of cases. Conclusions: Pathological results from TBLC and SLB were poorly concordant in the assessment of ILD. SLBs were more frequently concordant with the final diagnosis retained at MDA. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
1073449X
Volume :
199
Issue :
10
Database :
Complementary Index
Journal :
American Journal of Respiratory & Critical Care Medicine
Publication Type :
Academic Journal
Accession number :
136641270
Full Text :
https://doi.org/10.1164/rccm.201810-1947OC