Back to Search Start Over

Assessment of reproducibility and biological variability of fasting and postprandial plasma metabolite concentrations using 1H NMR spectroscopy.

Authors :
Li-Gao, Ruifang
Hughes, David A.
le Cessie, Saskia
de Mutsert, Renée
den Heijer, Martin
Rosendaal, Frits R.
Willems van Dijk, Ko
Timpson, Nicholas J.
Mook-Kanamori, Dennis O.
Source :
PLoS ONE; 6/20/2019, Vol. 14 Issue 6, p1-14, 14p
Publication Year :
2019

Abstract

Introduction: It is crucial to understand the factors that introduce variability before applying metabolomics to clinical and biomarker research. Objectives: We quantified technical and biological variability of both fasting and postprandial metabolite concentrations measured using <superscript>1</superscript>H NMR spectroscopy in plasma samples. Methods: In the Netherlands Epidemiology of Obesity study (n = 6,671), 148 metabolite concentrations (101 metabolites belonging to lipoprotein subclasses) were measured under fasting and postprandial states (150 minutes after a mixed liquid meal). Technical variability was evaluated among 265 fasting and 851 postprandial samples, with the identical blood plasma sample being measured twice by the same laboratory protocol. Biological reproducibility was assessed by measuring 165 individuals twice across time for evaluation of short- (<6 months) and long-term (>3 years) biological variability. Intra-class coefficients (ICCs) were used to assess variability. The ICCs of the fasting metabolites were compared with the postprandial metabolites using two-sided paired Wilcoxon test separately for short- and long-term measurements. Results: Both fasting and postprandial metabolite concentrations showed high technical reproducibility using <superscript>1</superscript>H NMR spectroscopy (median ICC = 0.99). Postprandial metabolite concentrations revealed slightly higher ICC scores than fasting ones in short-term repeat measures (median ICC in postprandial and fasting metabolite concentrations 0.72 versus 0.67, Wilcoxon p-value = 8.0×10<superscript>−14</superscript>). Variability did not increase further in a long-term repeat measure, with median ICC in postprandial of 0.64 and in fasting metabolite concentrations 0.66. Conclusion: Technical reproducibility is excellent. Biological reproducibility of postprandial metabolite concentrations showed a less or equal variability than fasting metabolite concentrations over time. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
19326203
Volume :
14
Issue :
6
Database :
Complementary Index
Journal :
PLoS ONE
Publication Type :
Academic Journal
Accession number :
137084388
Full Text :
https://doi.org/10.1371/journal.pone.0218549