Back to Search Start Over

Sensorless Low Switching Frequency Explicit Model Predictive Control of Induction Machines Fed by Neutral Point Clamped Inverter.

Authors :
Jofre, Matias
Llor, Ana M.
Silva, Cesar A.
Source :
IEEE Transactions on Industrial Electronics; Dec2019, Vol. 66 Issue 12, p9122-9128, 7p
Publication Year :
2019

Abstract

This paper proposes an explicit predictive current control scheme implemented with a low carrier frequency pulsewidth modulation (PWM) on an induction machine fed by a three-level neutral point clamped inverter. The PWM carrier and the main current sampling frequency are both set to 1 kHz, resulting in a 500 Hz average switching frequency per device, which is very suitable for large drive applications. The explicit predictive control is introduced to optimize the available bandwidth provided by such a low sampling frequency, maximizing the dynamic performance. The strategy has been tested in a 2.2-kW induction motor experimental prototype. [ABSTRACT FROM AUTHOR]