Back to Search Start Over

Evaluation of deformable image registration algorithm for determination of accumulated dose for brachytherapy of cervical cancer patients.

Authors :
Mohammadi, Reza
Mahdavi, Seied Rabi
Jaberi, Ramin
Siavashpour, Zahra
Janani, Leila
Meigooni, Ali Soleimani
Reiazi, Reza
Source :
Journal of Contemporary Brachytherapy; 2019, Vol. 11 Issue 5, p469-478, 10p
Publication Year :
2019

Abstract

Purpose: This study was designed to assess the dose accumulation (DA) of bladder and rectum between brachytherapy fractions using hybrid-based deformable image registration (DIR) and compare it with the simple summation (SS) approach of GEC-ESTRO in cervical cancer patients. Material and methods: Patients (n = 137) with cervical cancer treated with 3D conformal radiotherapy and three fractions of high-dose-rate brachytherapy were selected. CT images were acquired to delineate organs at risk and targets according to GEC-ESTRO recommendations. In order to determine the DA for the bladder and rectum, hybrid- based DIR was done for three different fractions of brachytherapy and the results were compared with the standard GEC-ESTRO method. Also, we performed a phantom study to calculate the uncertainty of the hybrid-based DIR algorithm for contour matching and dose mapping. Results: The mean ± standard deviation (SD) of the Dice similarity coefficient (DICE), Jaccard, Hausdorff distance (HD) and mean distance to agreement (MDA) in the DIR process were 0.94 ±0.02, 0.89 ±0.03, 8.44 ±3.56 and 0.72 ±0.22 for bladder and 0.89 ±0.05, 0.80 ±0.07, 15.46 ±10.14 and 1.19 ±0.59 for rectum, respectively. The median (Q1, Q3; maximum) GyEQD2 differences of total D2cc between DIR-based and SS methods for the bladder and rectum were reduced by -1.53 (-0.86, -2.98; -9.17) and -1.38 (-0.80, -2.14; -7.11), respectively. The mean ± SD of DICE, Jaccard, HD, and MDA for contour matching were 0.98 ±0.008, 0.97 ±0.01, 2.00 ±0.70 and 0.20 ±0.04, respectively for large deformation. Maximum uncertainty of dose mapping was about 3.58%. Conclusions: The hybrid-based DIR algorithm demonstrated low registration uncertainty for both contour matching and dose mapping. The DA difference between DIR-based and SS approaches was statistically significant for both bladder and rectum and hybrid-based DIR showed potential to assess DA between brachytherapy fractions. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
1689832X
Volume :
11
Issue :
5
Database :
Complementary Index
Journal :
Journal of Contemporary Brachytherapy
Publication Type :
Academic Journal
Accession number :
139637868
Full Text :
https://doi.org/10.5114/jcb.2019.88762