Back to Search
Start Over
A New Highly Selective Colorimetric and Fluorometric Coumarin-based Chemosensor for Hg2+.
- Source :
- Journal of Fluorescence; Sep2020, Vol. 30 Issue 5, p985-997, 13p
- Publication Year :
- 2020
-
Abstract
- A novel colorimetric and fluorometric method based on coumarin as signalling unit was developed for Hg<superscript>2+</superscript> recognition and quantification. Initially, the alkyne functionality was incorporated into a coumarin system and the resulting molecule showed higher specificity and sensitivity for Hg<superscript>2+</superscript> over other cations in both absorption and emission sensing assays. The Hg<superscript>2+</superscript> recognition was detected as visible colour change from colourless to yellow and as fluorescence quenching. The colour change was assigned to the increased intramolecular charge transfer (ICT) in the signalling unit upon Hg<superscript>2+</superscript> binding whereas a decline in the fluorescence intensity was ascribed to the heavy atom effect from Hg<superscript>2+</superscript>. In order to generate a material with high sensing performance level, alkyne-functionalized molecule was hosted into a polymeric material. The resulting functionalized polymer showed higher sensitivity and selectivity for Hg<superscript>2+</superscript> over its corresponding coumarin molecule. The investigation of the possible binding modes for Hg<superscript>2+</superscript> suggested both alkyne and triazole functionalities as potential binding sites for Hg<superscript>2+</superscript>. The limit of detection (LOD) and limit of quantification (LOQ) of the proposed method were evaluated and values less than a recommended maximum level of Hg<superscript>2+</superscript>contaminant in drinking water (2.00 μg/L) were obtained (LOD = 0.44 μg/L and LOQ = 1.33μg/L). The real-life application of the method was investigated using natural water samples containing Hg<superscript>2+</superscript> levels equivalent to the maximum tolerable concentration of Hg<superscript>2+</superscript> in drinking water. The outcomes suggested that the method could be used in the sensing and determination of Hg<superscript>2+</superscript> level of contaminant in the environment. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 10530509
- Volume :
- 30
- Issue :
- 5
- Database :
- Complementary Index
- Journal :
- Journal of Fluorescence
- Publication Type :
- Academic Journal
- Accession number :
- 145305359
- Full Text :
- https://doi.org/10.1007/s10895-020-02542-x