Back to Search Start Over

Determination of hydrophobic degree of paper packaging materials by a tracer-assisted headspace gas chromatography.

Authors :
Dai, Yi
Yu, Zhen-Hua
Wang, Hao
Zhan, Jian-Bo
Xie, Jiao
Yue, Bao-Shan
Xie, Wei-Qi
Chai, Xin-Sheng
Source :
Nordic Pulp & Paper Research Journal; Sep2020, Vol. 35 Issue 3, p370-375, 6p
Publication Year :
2020

Abstract

The present work reports on a method for the determination of hydrophobic degree of paper packaging material by tracer-assisted headspace gas chromatography. The method was based on adding 40 μL of methanol-water drop on the paper surface for 20 s. After removing the excess water by turning the sample vertically, the sample is placed in a vial and the amount of residual tracer attached on the material surface was accurately quantified by full evaporation headspace gas chromatography. The results show that the present method has a good precision (less than 4.1 %). The present method is simple and accurate and it can be an efficient tool for testing the hydrophobic degree of paper packaging material in batch. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
02832631
Volume :
35
Issue :
3
Database :
Complementary Index
Journal :
Nordic Pulp & Paper Research Journal
Publication Type :
Academic Journal
Accession number :
146347278
Full Text :
https://doi.org/10.1515/npprj-2020-0018