Back to Search Start Over

What Do the OMERACT Shoulder Core Set Candidate Instruments Measure? An Analysis Using the Refined International Classification of Functioning, Disability, and Health Linking Rules.

Authors :
Røe, Yngve
Buchbinder, Rachelle
Grotle, Margreth
Whittle, Samuel
Ramiro, Sofia
Huang, Hsiaomin
Gagnier, Joel
Verhagen, Arianne
Østensjø, Sigrid
Source :
Journal of Rheumatology; Oct2020, Vol. 47 Issue 10, p1557-1564, 8p
Publication Year :
2020

Abstract

<bold>Objective: </bold>The objective of this paper is to assess the content and measurement constructs of the candidate instruments for the domains of "pain" and "physical function/activity" in the Outcome Measures in Rheumatology (OMERACT) shoulder core set. The results of this International Classification of Functioning, Disability, and Health (ICF)-based analysis may inform further decisions on which instruments should ultimately be included in the core set.<bold>Methods: </bold>The materials for the analysis were the 13 candidate measurement instruments within pain and physical function/activity in the shoulder core domain set, which either passed or received amber ratings (meaning there were some issues with the instrument) in the OMERACT filtering process. The content of the candidate instruments was extracted and linked to the ICF using the refined linking rules. The linking rules enhance the comparability of instruments by providing a comprehensive overview of the content of the instruments, the context in which the measurements take place, the perspectives adopted, and the types of response options.<bold>Results: </bold>The ICF content analysis showed a large variation in content and measurement constructs in the candidate instruments for the shoulder core outcome measurement set.<bold>Conclusion: </bold>Two of 6 pain instruments include constructs other than pain. Within the physical function/activity domain, 2 candidate instruments matched the domain, 3 included additional content, and 2 included meaningful concepts in the response options, suggesting that they should be omitted as candidate instruments. The analyses show that the content in most existing instruments of shoulder pain and functioning extends across core set domains. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0315162X
Volume :
47
Issue :
10
Database :
Complementary Index
Journal :
Journal of Rheumatology
Publication Type :
Academic Journal
Accession number :
146370359
Full Text :
https://doi.org/10.3899/jrheum.190832