Back to Search Start Over

Six Months of Hybrid Closed-Loop Versus Manual Insulin Delivery With Fingerprick Blood Glucose Monitoring in Adults With Type 1 Diabetes: A Randomized, Controlled Trial.

Authors :
McAuley, Sybil A.
Lee, Melissa H.
Paldus, Barbora
Vogrin, Sara
de Bock, Martin I.
Abraham, Mary B.
Bach, Leon A.
Burt, Morton G.
Cohen, Neale D.
Colman, Peter G.
Davis, Elizabeth A.
Hendrieckx, Christel
Holmes-Walker, D. Jane
Kaye, Joey
Keech, Anthony C.
Kumareswaran, Kavita
MacIsaac, Richard J.
McCallum, Roland W.
Sims, Catriona M.
Speight, Jane
Source :
Diabetes Care; Dec2020, Vol. 43 Issue 12, p3024-3033, 10p
Publication Year :
2020

Abstract

<bold>Objective: </bold>To investigate glycemic and psychosocial outcomes with hybrid closed-loop (HCL) versus user-determined insulin dosing with multiple daily injections (MDI) or insulin pump (i.e., standard therapy for most adults with type 1 diabetes).<bold>Research Design and Methods: </bold>Adults with type 1 diabetes using MDI or insulin pump without continuous glucose monitoring (CGM) were randomized to 26 weeks of HCL (Medtronic 670G) or continuation of current therapy. The primary outcome was masked CGM time in range (TIR; 70-180 mg/dL) during the final 3 weeks.<bold>Results: </bold>Participants were randomized to HCL (n = 61) or control (n = 59). Baseline mean (SD) age was 44.2 (11.7) years, HbA1c was 7.4% (0.9%) (57 [10] mmol/mol), 53% were women, and 51% used MDI. HCL TIR increased from (baseline) 55% (13%) to (26 weeks) 70% (10%) with the control group unchanged: (baseline) 55% (12%) and (26 weeks) 55% (13%) (difference 15% [95% CI 11, 19]; P < 0.0001). For HCL, HbA1c was lower (median [95% CI] difference -0.4% [-0.6, -0.2]; -4 mmol/mol [-7, -2]; P < 0.0001) and diabetes-specific positive well-being was higher (difference 1.2 [95% CI 0.4, 1.9]; P < 0.0048) without a deterioration in diabetes distress, perceived sleep quality, or cognition. Seventeen (9 device-related) versus 13 serious adverse events occurred in the HCL and control groups, respectively.<bold>Conclusions: </bold>In adults with type 1 diabetes, 26 weeks of HCL improved TIR, HbA1c, and their sense of satisfaction from managing their diabetes compared with those continuing with user-determined insulin dosing and self-monitoring of blood glucose. For most people living with type 1 diabetes globally, this trial demonstrates that HCL is feasible, acceptable, and advantageous. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01495992
Volume :
43
Issue :
12
Database :
Complementary Index
Journal :
Diabetes Care
Publication Type :
Academic Journal
Accession number :
147097549
Full Text :
https://doi.org/10.2337/dc20-1447