Back to Search Start Over

Relevance of contact sensitizations in occupational dermatitis patients with special focus on patch testing of workplace materials.

Authors :
Schubert, Steffen
Geier, Johannes
Skudlik, Christoph
Reich, Anna
Hansen, Andreas
Buhl, Timo
Mempel, Martin
Schön, Michael P.
John, Swen M.
Brans, Richard
Source :
Contact Dermatitis (01051873); Dec2020, Vol. 83 Issue 6, p475-486, 12p
Publication Year :
2020

Abstract

Background: Studies on patch testing with workplace materials and evaluation of current occupational relevance of positive patch test reactions are scarce in patients with occupational dermatitis (OD). Objectives: To identify frequent sensitizations with occupational relevance and to determine the value of patch testing with workplace materials in OD patients. Patients and Methods: Results and clinical data of 654 patients with suspected OD patch tested between 2013 and 2017 were analysed. Results: Occupational allergic contact dermatitis was diagnosed in 113 (17.3%) patients. Mechanics had the widest range of occupational sensitizations. Sensitization to epoxy resin was rated occupationally relevant in almost all handicraft trades. Among positive patch test reactions to workplace products, those to water‐based metal working fluids and leave‐on cosmetic products were most frequent. Despite frequent testing, protective gloves only rarely elicited positive reactions. Preservatives and rubber compounds were most frequently identified as currently occupationally relevant. Conclusions: Rubber allergy is occupationally relevant especially in healthcare workers and cleaners. Generally, preservatives including formaldehyde releasers are important allergens in OD patients. Leave‐on cosmetic products must not be forgotten as allergen sources. Patch testing both workplace materials and standardized test preparations has a complementary value and is beneficial for the diagnostic work‐up of OD patients. Highlights: Patch testing of workplace materials and standardized test preparations has a complementary value in the diagnostic work‐up of occupational dermatitis patients.Mechanics should be patch tested in a broad fashion, including rubber, metal working fluids, epoxy resin systems, and leave‐on products.Epoxy resin systems exhibit current occupational relevance in almost all high‐risk professions of the handicraft sector. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01051873
Volume :
83
Issue :
6
Database :
Complementary Index
Journal :
Contact Dermatitis (01051873)
Publication Type :
Academic Journal
Accession number :
147176007
Full Text :
https://doi.org/10.1111/cod.13688