Practical Experience of Endoscope Reprocessing and Working- Platform Disinfection in COVID-19 Patients: A Report from Guangdong China during the Pandemic.

Authors :
Xianqi Lin
Zhenyi Zhang
Minzhao Gao
Zhenling Zhang
Zhidong Lin
Siwen Huang
Jiangnan Ren
Meijuan Luo
Xiaoqing Xu
Guilan Chen
Hongjun Chen
Renxu Lai
Xiaochun Wu
Lihua Zhang
Xiaofeng Li
Source :
Gastroenterology Research & Practice; 12/31/2020, Vol. 2020, p1-4, 4p
Publication Year :
2020

Abstract

Background. No consensus exists regarding which procedures should be performed to disinfect endoscopes and working platforms after COVID-19 patients have undergone endoscopy. Methods. We analyzed the disinfection quality of endoscopes and working platforms after 11 COVID-19 patients had undergone endoscopy. Conclusions. For endoscopic preprocessing at the bedside, a key disinfection step is using a multienzyme stock solution. The nucleic acid tests for endoscopists, washers, endoscopes, and working platforms were all negative. Based on our experience with the 11 COVID-19 patients who had undergone endoscopy, we provide an endoscopic reprocessing method for the bedside endoscopic diagnosis and treatment of COVID-19 patients for reference. [ABSTRACT FROM AUTHOR]