Evaluation of technical performance of optical surface imaging system using conventional and novel stereotactic radiosurgery algorithms.

Authors :
Kojima, Hironori
Takemura, Akihiro
Kurokawa, Shogo
Ueda, Shinichi
Noto, Kimiya
Yokoyama, Haruna
Takamatsu, Shigeyuki
Source :
Journal of Applied Clinical Medical Physics; Feb2021, Vol. 22 Issue 2, p58-68, 11p
Publication Year :
2021

Abstract

The Catalyst HD (C‐RAD Positioning AB, Uppsala, Sweden) optical surface imaging (OSI) system is able to manage interfractional patient positioning, intrafractional motion monitoring, and non‐contact respiratory gating without x‐ray exposure for radiation therapy. In recent years, a novel high‐precision surface registration algorithm for stereotactic radiosurgery (SRS algorithm) has been released. This study aimed to evaluate the technical performance of the OSI system using rigid phantoms, by comparing the conventional and SRS algorithms. To determine the system's technical performance, isocenter displacements were calculated by surface image registration via the OSI system using head, thorax, and pelvis rigid phantoms. The reproducibility of positioning was evaluated by the mean value calculated by repeating the registration 10 times, without moving each phantom. The accuracy of positioning was evaluated by the mean value of the residual error, where the 10 offset values given to each phantom were subtracted from the isocenter displacement values. The stability of motion monitoring was evaluated by measuring isocenter drift during 20 min and averaging it over 10 measurements. For the head phantom, all tests were compared with the mask types and algorithms. As a result, for all sites and both algorithms, the reproducibility, accuracy, and stability for translation and rotation were <0.1 mm and <0.1°, <1.0 mm and <1.0°, and <0.1 mm and <0.1°, respectively. In particular, the SRS algorithm had a small absolute error and standard deviation of calculated isocenter displacement, and a significantly higher reproducibility and accuracy than the conventional algorithm (P < 0.01). There was no difference in the stability between the algorithms (P = 0.0280). The SRS algorithm was found to be suitable for the treatment of rigid body sites with less deformation and small area, such as the head and face. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
15269914
Volume :
22
Issue :
2
Database :
Complementary Index
Journal :
Journal of Applied Clinical Medical Physics
Publication Type :
Academic Journal
Accession number :
148722476
Full Text :
https://doi.org/10.1002/acm2.13152