Total knee replacement wear during simulated gait with mechanical and anatomic alignments.

Authors :
Maag, Chase
Cracaoanu, Ioan
Langhorn, Jason
Heldreth, Mark
Source :
Proceedings of the Institution of Mechanical Engineers -- Part H -- Journal of Engineering in Medicine (Sage Publications, Ltd.); May2021, Vol. 235 Issue 5, p515-522, 8p
Publication Year :
2021

Abstract

Total knee replacements (TKR) have historically been implanted perpendicular to the mechanical axis of the knee joint, with a commensurate external rotation of the femur in flexion relative to the posterior condylar axis (PCA). Although this mechanical alignment (MA) method has typically offered good long-term survivorship of implants, it may result in alignment of the implant that departs significantly from the native Joint Line (JL) in extension and flexion for a considerable portion of the patient population. There is a growing interest with surgeons to implant TKR components more closely aligned to the natural JL (Anatomic Alignment-AA) of the patient's knee joint to reduce the need for soft tissue releases during surgery, potentially improving knee function and patient satisfaction. Using a previously-validated finite element model of the lower extremity, implant- and alignment-specific loading conditions were developed and applied in a wear experiment via a six-degree-of-freedom joint simulator. MA was defined as 0° Joint Line (JL), 0° varus hip-knee-ankle (HKA) angle, and 3° external femoral rotation. AA was defined as 5° varus JL, 3° varus HKA, and 0° femoral rotation. The experiment returned wear rates of 3.76 ± 0.51 mg/million cycles (Mcyc) and 2.59 ± 2.11 mg/Mcyc for ATTUNE<superscript>®</superscript> cruciate-retaining (CR) fixed bearing (FB) in MA and AA, respectively. For ATTUNE posterior-stabilized (PS) FB in AA, the wear rate was 0.97 ± 1.11 mg/Mcyc. For ATTUNE CR rotating platform (RP), the wear rates were 0.23 ± 0.19 mg/Mcyc, 0.48 ± 1.02 mg/Mcyc in MA and AA respectively. Using a two-way ANOVA, it was determined that there was no significantly difference in the wear rates between AA and MA (p = 0.144) nor the wear rate of ATTUNE PS FB in AA significantly different from either ATTUNE CR FB or ATTUNE CR RP. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09544119
Volume :
235
Issue :
5
Database :
Complementary Index
Journal :
Proceedings of the Institution of Mechanical Engineers -- Part H -- Journal of Engineering in Medicine (Sage Publications, Ltd.)
Publication Type :
Academic Journal
Accession number :
149986804
Full Text :
https://doi.org/10.1177/0954411921991269