Towards a versatile and economic Chagas Disease point-of-care testing system, by integrating loop-mediated isothermal amplification and contactless/label-free conductivity detection.
- Source :
- PLoS Neglected Tropical Diseases; 5/14/2021, Vol. 15 Issue 5, p1-15, 15p
- Publication Year :
- 2021
-
Abstract
- Rapid diagnosis by using small, simple, and portable devices could represent one of the best strategies to limit the damage and contain the spread of viral, bacterial or protozoa diseases, principally when they can be transmitted by air and are highly contagious, as some respiratory viruses are. The presence of antibodies in blood or serum samples is not the best option for deciding when a person must be quarantined to stop transmission of disease, given that cured patients have antibodies, so the best diagnosis methods rely on the use of nucleic acid amplification procedures. Here we present a very simple device and detection principle, based a paper discs coupled to contactless conductivity (C<superscript>4</superscript>D) sensors, can provide fast and easy diagnostics that are needed when an epidemic outbreak develops. The paper device presented here solves one of the main drawbacks that nucleic acid amplification tests have when they are performed outside of central laboratories. As the device is sealed before amplification and integrally disposed in this way, amplimers release cannot occur, allowing repetitive testing in the physician's practice, ambulances, or other places that are not prepared to avoid cross-contamination of new samples. The use of very low volume samples allows efficient reagent use and the development of low cost, simple, and disposable point-of-care diagnostic systems. Author summary: In 2005, the World Health Organization (WHO) recognized Chagas Disease as a neglected tropical disease. Meanwhile the serological tests, recommended by WHO, can be performed for chronic disease diagnosis, the nucleic acid amplification tests must be performed for the detection of the acute phase of the disease. Although the existing laboratory diagnosis tests for Chagas Disease are sensitive and highly reproducible, they cannot be performed in rural, low infrastructure environments, where this disease prevails. In this sense, the use of simple and portable analytical devices may be able to offer an affordable solution to this problem, allowing fast sampling, diagnosis and treatment prescription in one simple and fast intervention, as the performed by short term medical missions. In this study we show for the first time a diagnosis test comprising low cost materials and employing a contactless and label-free conductivity detection system that is used to read the result of a nucleic acid amplification reaction. The test showed high sensitivity for Chagas Disease diagnosis showing the potential to be used in rural and low income places. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 19352727
- Volume :
- 15
- Issue :
- 5
- Database :
- Complementary Index
- Journal :
- PLoS Neglected Tropical Diseases
- Publication Type :
- Academic Journal
- Accession number :
- 150321438
- Full Text :
- https://doi.org/10.1371/journal.pntd.0009406