Aim: The Aim of the study was to evaluate the reproducibility of condylar inclination values obtained using three different interocclusal recording materials in Hanau Wide-Vue semi-adjustable articulator and tocompare those values of condylar inclination with panoramic radiographic images. Settings and Design: In Vivo Comparative study. Materials and Methods: The clinical trial was carried out in the Department of Prosthodontics, M. R Ambedkar Dental College and Hospital, Bengaluru. A total of 30 dentulous subjects aged between 20 and 40 years were selected, without any signs and symptoms of temporomandibular joint disorders. With the help of a custom-made protrusive guide, protrusive records for three materials were made. These records were used for programming the articulator and the respective horizontal condylar inclination (HCI) value, and panoramic radiographs were made. The values obtained were statistically analyzed. Statistical Analysis Used: Independent t-test, multiple comparisons using Bonferroni method followed by Analysis of variances (ANOVA) were used. Results: Among each pair of groups there exists a significant difference, i.e., the mean condylar inclination (degree) was found to be statistically significant between wax and polyvinyl siloxane (P < 0.01) as well as between wax and polyether (P < 0.01). No significant difference was observed between polyvinyl siloxane and polyether (P > 0.05). Conclusion: HCI values differed depending on the type of material employed. The study concluded that the protrusive condylar guidance angles obtained by panoramic radiograph can be used in programming the semi-adjustable articulator and among the materials polyether gave the highest Condylar Guidance values with less variability and wax gave lowest values with greater variation. [ABSTRACT FROM AUTHOR]

Subjects

Subjects :
DENTAL articulators
RADIOGRAPHS

Details

Language :
English
ISSN :
09724052
Volume :
21
Issue :
4
Database :
Complementary Index
Journal :
Journal of Indian Prosthodontic Society
Publication Type :
Academic Journal
Accession number :
153671825
Full Text :
https://doi.org/10.4103/jips.jips_239_21