Back to Search Start Over

An Impact-Echo Experimental Approach for Detecting Concrete Structural Faults.

Authors :
Yang, Ya-xun
Chai, Wen-hao
Liu, De-chuang
Zhang, Wei-de
Lu, Jia-cheng
Yang, Zhi-kui
Source :
Advances in Civil Engineering; 12/20/2021, p1-8, 8p
Publication Year :
2021

Abstract

For the current problem of detection of grouting defects in posttensioned prestressed concrete members, the paper takes a single-layer arrangement of prestressed pipes as the object of study. The influence law of the main factors such as pipe material, defect size, defect critical surface location, and prestressing reinforcement location on the results of the impact-echo method for detecting concrete grouting defects was studied. Firstly, the ABAQUS finite element software was used to simulate these factors to obtain the influence law on the detection results, and a modal test was conducted to verify them. The results show that the impact-echo method can effectively test the location of defects and the degree of burial depth, and the pipe material influences the test results, and the impact of corrugated metal pipe is smaller and more accurate than the PVC pipe. In addition, the greater the plate thickness frequency drift rate, the larger the transverse size of the defect, so the plate thickness frequency drift rate and the measured defect depth are combined to quantitatively determine the depth of the defect. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
16878086
Database :
Complementary Index
Journal :
Advances in Civil Engineering
Publication Type :
Academic Journal
Accession number :
154216987
Full Text :
https://doi.org/10.1155/2021/8141015