Back to Search Start Over

The Diagnostic and Grading Accuracy of 68Ga-DOTATATE and 18F-FDG PET/MR for Pancreatic Neuroendocrine Neoplasms.

Authors :
Zhou, Jinxin
Zhao, Runze
Pan, Yu
Ju, Huijun
Huang, Xinyun
Jiang, Yu
Jin, Jiabin
Zhang, Yifan
Source :
Frontiers in Oncology; 2/22/2022, Vol. 12, p1-10, 10p
Publication Year :
2022

Abstract

Accurate diagnosis and grading are critical for pancreatic neuroendocrine neoplasm (pNEN) management. This study compares the diagnostic and grading value of <superscript>68</superscript>Ga-DOTATATE PET/MR and <superscript>18</superscript>F-FDG PET/MR for pNENs separately as well as in combination. A total of 36 patients with histologically confirmed pNENs, who underwent both <superscript>68</superscript>Ga-DOTATATE PET/MR and <superscript>18</superscript>F-FDG PET/MR within 2 weeks from 2020 to 2021, were retrospectively collected and analyzed. The maximum standardized uptake values of <superscript>68</superscript>Ga-DOTATATE (G-SUVmax) and <superscript>18</superscript>F-FDG (F-SUVmax) on PET and the minimum values of apparent diffusion coefficient (ADCmin) on MR were measured on the lesions with known histological grading (25 by surgery, 11 by biopsy). Receiver-operating characteristic analysis was applied to determine the cutoffs of these parameters or their combinations for differentiation between G1 and G2, as well as between low-grade and high-grade pNENs. The Spearman rank correlation coefficient was used to assess the correlation between the imaging parameters and the maximum tumor diameters. The detection rate of <superscript>68</superscript>Ga-DOTATATE PET imaging alone was 95%, 87.5%, and 37.5% for G1, G2, and G3, respectively. Adding <superscript>18</superscript>F-FDG PET or MR sequences of PET/MR increased the detection rate to 100% in all grades. Among the three parameters, G-SUVmax had the highest diagnostic rate in predicting tumor grade. It presented a sensitivity of 87.5% and a specificity of 80.0% with a cutoff value of 42.75 for differentiating G2 from G1 pNETs and a sensitivity and specificity of 100% and 71.4% with a cutoff value of 32.75 in predicting high-grade pNENs. The ratio of G-SUVmax to F-SUVmax (G-SUVmax/F-SUVmax) showed slight improvement in the diagnostic rate, while the product of G-SUVmax and ADCmin (G-SUVmax*ADCmin) did not improve the diagnostic rate. <superscript>68</superscript>Ga-DOTATATE PET/MR alone is sufficient for the diagnosis of pNENs and the prediction of various grades. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
2234943X
Volume :
12
Database :
Complementary Index
Journal :
Frontiers in Oncology
Publication Type :
Academic Journal
Accession number :
155378290
Full Text :
https://doi.org/10.3389/fonc.2022.796391