Back to Search Start Over

Routine Early Computed Tomography Scanner After Laparoscopic Sleeve Gastrectomy in High-Risk Severely Obese Patients Is Effective for Bleeding or Hematoma Diagnosis but not for Staple-Line Leak Detection: a Prospective Study.

Authors :
Lainas, Panagiotis
Triantafyllou, Evangelia
Chagué, Pierre
Dammaro, Carmelisa
Maitre, Sophie
Rocher, Laurence
Dagher, Ibrahim
Source :
Obesity Surgery; May2022, Vol. 32 Issue 5, p1624-1630, 7p
Publication Year :
2022

Abstract

Purpose: Laparoscopic sleeve gastrectomy (LSG) is the most frequently performed bariatric procedure worldwide. Postoperative staple-line leak and intraabdominal hemorrhage can increase associated morbidity and mortality. The value of routine early computed tomography (CT) scanner examination in the early diagnosis of complications in high-risk severely obese patients undergoing LSG is studied. Methods: This was a prospective, non-randomized study including all patients undergoing LSG in our department from 2014 to 2020. Patients presenting at least one potential risk factor for postoperative gastric leak and bleeding (as defined by the current literature) were included. Primary endpoint was the efficacy of postoperative day (POD) 2 CT-scanner examination in diagnosing these complications. Results: One thousand fifty-one high-risk patients were included. Median age was 44 years. Early postoperative surgical complications occurred in 48 patients (4.5%): 25 (2.3%) intraabdominal hemorrhage and 23 (2.2%) staple-line leak. Early CT-scanner detected intraabdominal bleeding or hematoma in 22/25 patients, with 95.6% sensitivity (Youden's index = 0.95), while specificity was 100%, positive predictive value (PPV) 100%, and negative predictive value (NPV) 99.9%. Sensitivity of early postoperative CT-scanner was 43.4% (10/23 patients; Youden's index = 0.43) for staple-line leak detection, with specificity of 100%, PPV 100%, and NPV 98.7%. Conclusion: POD 2 CT-scanner in high-risk severely obese patients undergoing LSG is an excellent tool for early diagnosis of intraabdominal hemorrhage, but sensitivity remains low for staple-line leak detection. Close postoperative clinical follow-up of these patients is essential and any suspicion of postoperative surgical complication should motivate the performance of a CT-scanner. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09608923
Volume :
32
Issue :
5
Database :
Complementary Index
Journal :
Obesity Surgery
Publication Type :
Academic Journal
Accession number :
156152488
Full Text :
https://doi.org/10.1007/s11695-022-05997-y