Back to Search Start Over

Preliminary results on the bird protection effectiveness of animal deflectors on railway overhead lines based on electrical current evaluation.

Authors :
Kornhuber, Stefan
Pampel, Hans-Peter
Görlich, Jana
Leiblein-Wild, Marion
Jöckle, Christoph
Source :
Nature Conservation; 2022, Issue 47, p317-333, 17p
Publication Year :
2022

Abstract

In contrast to other transportation systems, railway systems feature special characteristics, which may cause specific hazards to birds. Among other things, there is the risk of electrocutions resulting from short circuits. To protect the birds and minimize these short circuit events, the DB Netz AG has installed so-called animal deflectors on the insulators of the overhead lines. Since this effort, the number of short-circuit events in the respective sections has decreased, according to DB Netz AG. The principal mechanism of action of the animal deflectors is based on mechanical defense, combined with electrostatic discharge on contact. Although the number of short circuit events has been reduced by using animal de- flectors, the detailed function of the animal deflector in different environmental conditions has not been investigated up to now. This research project aims to determine whether, and to what extent, the use of animal deflectors in retrofitting overhead lines may contribute to bird protection and which currents can be measured at retrofitted insulators under different environmental conditions. Hence the current should be measured when using animal deflectors on railway overhead lines for different isolator states and body resistances (5 kΩ, 3 kΩ, 1kΩ, 0.5 kΩ). The results show an influence of measured current depending on the insulator state. Our preliminary results indicate that the use of an animal deflector (KTA) to the tested polymeric insulator and pollution severity can be recommended, since, based on the investigations, no danger to small birds and small animals can be identified. However, the use of the animal deflector (KTA) for the tested porcelain insulator and pollution severity should not be recommended as they showed high animal hazards during pollution and fog conditions. However, these results cannot be transferred to other different insulator types and pollution severities. Investigating the electrical current to the type of insulator used and the expected pollution severity is recommended. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
13146947
Issue :
47
Database :
Complementary Index
Journal :
Nature Conservation
Publication Type :
Academic Journal
Accession number :
156509506
Full Text :
https://doi.org/10.3897/natureconservation.47.70704