Echocardiographic assessment of intimal thickness growth of patent ductus arteriosus in neonates and analysis of influencing factors.

Authors :
Hu, Xin-Lu
Wang, Hui
Hou, Cui
Hou, Miao
Zhan, Shi-Hong
Pan, Tao
Ding, Yue-Yue
Gu, Pei-Pei
Xu, Qiu-Qin
Source :
International Journal of Cardiovascular Imaging; Jul2022, Vol. 38 Issue 7, p1443-1452, 10p
Publication Year :
2022

Abstract

The spontaneous closure rate of patent ductus arteriosus (PDA) is high, and the necessity of early intervention is debated. Quantitative echocardiographic assessment of the intima in PDA has not been reported. This study evaluated intimal thickness growth in neonatal cases of PDA via echocardiography and investigated its correlation with clinical factors. Seventy-three neonates were enrolled, and echocardiography was performed three times: within 24 h post-birth (first echo), 48 h after the first echo (second echo), and before discharge (third echo). According to PDA outcome, the neonates were divided into the PDA-open group (n = 18 cases), PDA-closure at second echo group (n = 32 cases), and non-PDA at first echo group (n = 23 cases). We measured the intimal thickness (IT1 and IT2 at first and second echo, respectively), lumen diameter of ductus arteriosus (D1 and D2 at first and second echo, respectively), IT1/D1 ratio, and intimal thickness growth rate (V). Correlations between echocardiographic indicators, perinatal factors, and clinical treatment were analyzed. On first echo, the PDA-open group showed a significantly lower IT1/D1 than the combined PDA-closure group (P < 0.05). On second echo, the PDA-open group showed a significantly lower IT2 and V than the PDA-closure group as well as a significantly higher D2 (P < 0.05). Smaller gestational age correlated with a larger D2 but smaller IT2 and V (P < 0.05) and a higher level of respiratory support within 72 h post-birth correlated with a larger D2 and smaller IT 2 (P < 0.05). Increasing oxygen demand within 72 h of birth correlated with a larger D1 and D2 (P < 0.05). Echocardiographic assessment of intimal thickness growth in PDA may provide an approach for predicting spontaneous PDA closure, thereby guiding decision-making regarding early intervention. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
15695794
Volume :
38
Issue :
7
Database :
Complementary Index
Journal :
International Journal of Cardiovascular Imaging
Publication Type :
Academic Journal
Accession number :
157928225
Full Text :
https://doi.org/10.1007/s10554-022-02531-0