Back to Search Start Over

Long-term follow-up for monovision surgery by Implantable Collamer Lens V4c implantation for myopia correction in early presbyopia.

Authors :
Ye, Yuhao
Zhao, Jing
Zhang, Zhe
Niu, Lingling
Shi, Wanru
Wang, Xiaoying
Zhou, Xingtao
Source :
Graefe's Archive of Clinical & Experimental Ophthalmology; Aug2022, Vol. 260 Issue 8, p2763-2771, 9p
Publication Year :
2022

Abstract

Purpose: To investigate the long-term safety and efficacy of monovision surgery using implantable collamer lens V4c (ICL V4c) implantation in myopic patients with early presbyopia. Setting: Eye and ENT Hospital of Fudan University, Shanghai, China. Design: Prospective case series study. Methods: This study included 64 eyes of 32 patients with early presbyopia, who underwent bilateral ICL V4c implantation for myopia correction. Parameters, including mean spherical equivalent (SE), uncorrected distance visual acuity, corrected distance visual acuity, intraocular pressure, endothelial cell density, presbyopic add power, visual acuity (logMAR) of dominant eyes (D-eye), nondominant (nD-eye) eyes, and both eyes (Bi) at 0.4 m, 0.8 m, and 5 m were recorded at the last follow-up. Results: All surgeries were uneventful. At the last follow-up, the safety indices were 1.23 ± 0.18 (D-eyes) and 1.21 ± 0.18 (nD-eyes) (p > 0.05); the efficacy indices were 0.95 ± 0.27 (D-eyes) and 0.92 ± 0.28 (nD-eyes) (p < 0.05), the SE was -0.62 ± 0.47 D (D-eyes); and − 1.21 ± 0.78D (nD-eyes) (p < 0.05), presbyopic add power was 1.31 ± 0.58 D. The visual acuity (logMAR) of D-eyes, nD-eyes, and binocular (Bi) at 5.0 m were: 0.06 ± 0.15 (D-eye), 0.21 ± 0.18 (nD-eye), (p < 0.01), and 0.04 ± 0.13 (Bi); 0.8 m: 0.03 ± 0.18 (D-eye), 0.08 ± 0.16 (nD-eye), (p > 0.05), and − 0.02 ± 0.11 (Bi); 0.4 m: 0.08 ± 0.09 (D-eye), − 0.02 ± 0.08 (nD-eye), (p < 0.001), and − 0.03 ± 0.09 (Bi). Subjects were very satisfied or felt excellent with their visual acuity at near (81.25%) and far distances (87.50%), respectively (versus preoperative, p < 0.001). Conclusion: Monovision surgery using ICL V4c implantation is safe and practicable for correction of myopes with presbyopia, with long-term efficacy at near and far distances and patient satisfaction. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0721832X
Volume :
260
Issue :
8
Database :
Complementary Index
Journal :
Graefe's Archive of Clinical & Experimental Ophthalmology
Publication Type :
Academic Journal
Accession number :
158181406
Full Text :
https://doi.org/10.1007/s00417-021-05545-x