Back to Search Start Over

Effect of A Clinical-Replicable Cooling Protocol on the Cyclic Fatigue Resistance of Heat-Treated Nickel-Titanium Instruments.

Authors :
Heck, Luana
Weissheimer, Theodoro
Souza Calefi, Pedro Henrique
Priori Alcalde, Murilo
Ricci Vivan, Rodrigo
Abreu da Rosa, Ricardo
Húngaro Duarte, Marco Antonio
Reis Só, Marcus Vinicius
Source :
Iranian Endodontic Journal; Summer2022, Vol. 17 Issue 3, p132-137, 6p
Publication Year :
2022

Abstract

Introduction: The aim of this study was to evaluate the bending and cyclic fatigue resistance of Wave One Gold (WOG) and XI Blue (X1B) instruments when tested at body temperature (36°C ± 1°C) with and without subjected to an alloy cooling protocol. Materials and Methods: A total of sixty instruments (n=30) were tested. Forty instruments (n=20) were randomly selected and divided into two groups: body temperature (BT; n=20) and body temperature with cooling protocol (CP; n=20). Cyclic fatigue test was performed until fracture in a conventional stainless-steel device with water bath equipment to simulate body temperature. CP group instruments were subjected to 5 seconds of spray cooling every 30 seconds. Time to fracture was recorded in seconds. Resistance to bending at an angle of 45 degrees was evaluated using twenty instruments (n=10). Fractured surfaces were examined under scanning electron microscopy (SEM). Statistical analysis was performed at a 5% significance level. Results: There was no difference in the cyclic fatigue resistance between instruments in BT groups (P>0.05). Cooling protocol significantly increased the cyclic fatigue resistance of X1B instruments (P=0.0003) and WOG instruments (P=0.0003). Results: WOG instruments had a significantly lower cyclic fatigue resistance compared to X1B instruments in CP group (P=0.0001). There were no significant differences between the values of resistance increase presented by the instruments after cooling (P>0.05). Bending test presented no statistically significant differences between the tested instruments (P>0.05). Both instruments in both groups showed typical features of cyclic fatigue behavior under SEM. Conclusions: XI Blue #25.06 and WaveOne Gold #25.07 instruments presented similar cyclic fatigue resistance. The investigated clinical-replicable cooling protocol improved the cyclic fatigue resistance of the tested instruments, with XI Blue #25.06 presenting a greater cyclic fatigue resistance after cooling. Both instruments presented a similar bending capacity. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
17357497
Volume :
17
Issue :
3
Database :
Complementary Index
Journal :
Iranian Endodontic Journal
Publication Type :
Academic Journal
Accession number :
158710029
Full Text :
https://doi.org/10.22037/iej.v17i3.37210