Outcomes of novel 3D-printed fully porous titanium cup and a cemented highly cross-linked polyethylene liner in complex and revision total hip arthroplasty.

Authors :
Shichman, Ittai
Somerville, Lyndsay
Lutes, William B.
Jones, Stephen A.
McCalden, Richard
Schwarzkopf, Ran
Source :
Arthroplasty; 12/2/2022, Vol. 4 Issue 1, p1-8, 8p
Publication Year :
2022

Abstract

Introduction: A novel fully porous acetabular titanium shell has been designed to reduce stiffness mismatch between bone and implant and promote osseointegration in complex (cTHA) and revision total hip arthroplasty (rTHA). A highly cross-linked polyethylene (XLPE) liner is cemented within the cup to reduce wear rates and increase survivorship. This study reported the outcomes of an XLPE liner cemented into a novel 3D-printed fully porous cup in cTHA and rTHA. Methods: Presented was a multicenter retrospective review of 40 patients (6 cTHA and 34 rTHA) who underwent THA with a fully porous titanium acetabular cup and cemented XLPE liner. Data were collected on demographics, surgical information, outcomes, including osseointegration and migration and implant survivorship. Results: On average, patients were 71.42 ± 9.97 years old and obese (BMI: 30.36 ± 6.88 kg/m<superscript>2</superscript>) and were followed up for a mean time of 2.21 ± 0.77 years. Six patients underwent cTHA and 34 patients underwent rTHA. The mean hospital length of stay was 5.34 ± 3.34 days. Three (7.5%) 90-day readmissions were noted. Harris Hip Scores improved, on average, from 53.87 ± 12.58 preoperatively to 83.53 ± 12.15 postoperatively (P<0.001). One case of acetabular shell aspetic loosening with migration was noted. Thirty-nine of the 40 acetabular components were fully osseointegrated without migration. Two patients underwent re-revision surgery for PJI and one patient received acetabular shell+liner re-revision due to aseptic loosening. Kaplan-Meier analysis showed an all-cause revision-free survival rate of 95.0% at 6 months and 1 year, and 92.0% at 4-years. Aseptic acetabular cup, liner dislocation/loosening, and fracture-free survival was 100% at 6 months and 1-year, and 97.1% at 2 years. Conclusion: The combined use of a novel 3D-printed fully porous titanium acetabular shell and cemented XLPE acetabular liner yielded excellent rates of osseointegration, and all-cause and acetabular aseptic loosening survivorship at a minimum 1-year follow-up. Further long-term studies are needed to assess the longevity of this construct. [ABSTRACT FROM AUTHOR]

Details

Language :
English
Volume :
4
Issue :
1
Database :
Complementary Index
Journal :
Arthroplasty
Publication Type :
Academic Journal
Accession number :
160540624
Full Text :
https://doi.org/10.1186/s42836-022-00152-5