Back to Search Start Over

Improving total body irradiation with a dedicated couch and 3D-printed patient-specific lung blocks: A feasibility study.

Authors :
Strolin, Silvia
Paolani, Giulia
Santoro, Miriam
Cercenelli, Laura
Bortolani, Barbara
Ammendolia, Ilario
Cammelli, Silvia
Cicoria, Gianfranco
Phyo Wai Win
Morganti, Alessio G.
Marcelli, Emanuela
Strigari, Lidia
Source :
Frontiers in Oncology; 1/19/2023, Vol. 13, p1-14, 14p
Publication Year :
2023

Abstract

Introduction: Total body irradiation (TBI) is an important component of the conditioning regimen in patients undergoing hematopoietic stem cell transplants. TBI is used in very few patients and therefore it is generally delivered with standard linear accelerators (LINACs) and not with dedicated devices. Severe pulmonary toxicity is the most common adverse effect after TBI, and patient-specific lead blocks are used to reduce mean lung dose. In this context, online treatment setup is crucial to achieve precise positioning of the lung blocks. Therefore, in this study we aim to report our experience at generating 3D-printed patient-specific lung blocks and coupling a dedicated couch (with an integrated onboard image device) with a modern LINAC for TBI treatment. Material and methods: TBI was planned and delivered (2Gy/fraction given twice a day, over 3 days) to 15 patients. Online images, to be compared with planned digitally reconstructed radiographies, were acquired with the couch-dedicated Electronic Portal Imaging Device (EPID) panel and imported in the iView software using a homemade Graphical User Interface (GUI). In vivo dosimetry, using Metal-Oxide Field-Effect Transistors (MOSFETs), was used to assess the setup reproducibility in both supine and prone positions. Results: 3D printing of lung blocks was feasible for all planned patients using a stereolithography 3D printer with a build volume of 14.5Ã--14.5Ã--17.5 cm³. The number of required pre-TBI EPID-images generally decreases after the first fraction. In patient-specific quality assurance, the difference between measured and calculated dose was generally<2%. The MOSFET measurements reproducibility along each treatment and patient was 2.7%, in average. Conclusion: The TBI technique was successfully implemented, demonstrating that our approach is feasible, flexible, and cost-effective. The use of 3D-printed patient-specific lung blocks have the potential to personalize TBI treatment and to refine the shape of the blocks before delivery, making them extremely versatile. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
2234943X
Volume :
13
Database :
Complementary Index
Journal :
Frontiers in Oncology
Publication Type :
Academic Journal
Accession number :
161784753
Full Text :
https://doi.org/10.3389/fonc.2022.1046168