Back to Search Start Over

Validity and reliability of the Patient-Reported Outcomes Measurement Information System (PROMIS®) using computerized adaptive testing in patients with advanced chronic kidney disease.

Authors :
Willik, Esmee M van der
Breda, Fenna van
Jaarsveld, Brigit C van
van de Putte, Marlon
Jetten, Isabelle W
Dekker, Friedo W
Meuleman, Yvette
Ittersum, Frans J van
Terwee, Caroline B
Source :
Nephrology Dialysis Transplantation; May2023, Vol. 38 Issue 5, p1158-1169, 12p
Publication Year :
2023

Abstract

Background The Patient-Reported Outcomes Measurement Information System (PROMIS<superscript>®</superscript>) has been recommended for computerized adaptive testing (CAT) of health-related quality of life. This study compared the content, validity, and reliability of seven PROMIS CATs to the 12-item Short-Form Health Survey (SF-12) in patients with advanced chronic kidney disease. Methods Adult patients with chronic kidney disease and an estimated glomerular filtration rate under 30 mL/min/1.73 m<superscript>2</superscript> who were not receiving dialysis treatment completed seven PROMIS CATs (assessing physical function, pain interference, fatigue, sleep disturbance, anxiety, depression, and the ability to participate in social roles and activities), the SF-12, and the PROMIS Pain Intensity single item and Dialysis Symptom Index at inclusion and 2 weeks. A content comparison was performed between PROMIS CATs and the SF-12. Construct validity of PROMIS CATs was assessed using Pearson's correlations. We assessed the test-retest reliability of all patient-reported outcome measures by calculating the intraclass correlation coefficient and minimal detectable change. Results In total, 207 patients participated in the study. A median of 45 items (10 minutes) were completed for PROMIS CATs. All PROMIS CATs showed evidence of sufficient construct validity. PROMIS CATs, most SF-12 domains and summary scores, and Dialysis Symptom Index showed sufficient test-retest reliability (intraclass correlation coefficient ≥ 0.70). PROMIS CATs had a lower minimal detectable change compared with the SF-12 (range, 5.7–7.4 compared with 11.3–21.7 across domains, respectively). Conclusion PROMIS CATs showed sufficient construct validity and test-retest reliability in patients with advanced chronic kidney disease. PROMIS CATs required more items but showed better reliability than the SF-12. Future research is needed to investigate the feasibility of PROMIS CATs for routine nephrology care. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09310509
Volume :
38
Issue :
5
Database :
Complementary Index
Journal :
Nephrology Dialysis Transplantation
Publication Type :
Academic Journal
Accession number :
163536593
Full Text :
https://doi.org/10.1093/ndt/gfac231