Back to Search Start Over

Cross-sectional audit assessing the quality of dried bloodspot specimens received by UK metabolic biochemistry laboratories for the biochemical monitoring of individuals with Phenylketonuria.

Authors :
Hogg, Sarah L
Carling, Rachel S
Cantley, Nathan WP
Hamilton, Gillian
Goddard, Philippa
Aitkenhead, Helen
Barski, Robert
Collingwood, Catherine
Moat, Stuart J
Kemp, Helena J
Source :
Annals of Clinical Biochemistry; May2023, Vol. 60 Issue 3, p208-211, 4p
Publication Year :
2023

Abstract

Background: Sapropterin has been approved as a treatment option for individuals with Phenylketonuria in the United Kingdom. Individuals are assessed as responsive to Sapropterin by a ≥30% reduction in Phenylalanine (Phe) concentrations using dried blood spot (DBS) specimens. DBS quality is critical for accurate and precise measurement of Phe. Currently, UK national guidelines for DBS specimen acceptance do not exist for patient-collected DBS specimens. We adopted evidence-based guidelines for specimen acceptance criteria and retrospectively assessed the impact of introducing these guidelines on specimen rejection rates. Methods: Laboratories were invited to audit the quality of DBS specimens routinely received for Phe monitoring using: (1) existing acceptance/rejection criteria and (2) proposed national guidelines. Results: Ten laboratories audited 2111 specimens from 1094 individuals. Using existing local guidelines, the median rejection rate was 4.0% (IQR 1.5–7.2%). This increased to 21.9% (IQR 10.0–33.0%) using the proposed guidelines. Where reason(s) for rejection were provided (n = 299); 211/299 (70.6%) of DBS specimens were too small or multi-spotted. 380 individuals had more than one sample evaluated; 231/380 (60.8%) provided specimens of acceptable quality, 37/380 (9.7%) consistently provided poor-quality DBS specimens. Conclusions: There is significant variability in the quality of patient-collected DBS specimens. If unacceptable specimens are not rejected, imprecise/inaccurate results will be used in clinical decision making. Using annual workload data for England, this equates to 12,410 incorrect results. Individuals and parents/carers should receive ongoing training in blood collection technique to ensure use of evidence-based acceptability criteria does not cause undue distress from increased sample rejection rates. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00045632
Volume :
60
Issue :
3
Database :
Complementary Index
Journal :
Annals of Clinical Biochemistry
Publication Type :
Academic Journal
Accession number :
163635569
Full Text :
https://doi.org/10.1177/00045632231156035