Back to Search Start Over

Potential of Lesion‐to‐Fat Elasticity Ratio Measured by Shear Wave Elastography to Reduce Benign Biopsies in BI‐RADS 4 Breast Lesions.

Authors :
Togawa, Riku
Pfob, André
Büsch, Christopher
Alwafai, Zaher
Balleyguier, Corinne
Clevert, Dirk‐André
Duda, Volker
Fastner, Sarah
Goncalo, Manuela
Gomez, Christina
Gruber, Ines
Hahn, Markus
Hennigs, André
Kapetas, Panagiotis
Nees, Juliane
Ohlinger, Ralf
Riedel, Fabian
Rutten, Matthieu
Schäfgen, Benedikt
Stieber, Anne
Source :
Journal of Ultrasound in Medicine; Aug2023, Vol. 42 Issue 8, p1729-1736, 8p
Publication Year :
2023

Abstract

Objectives: We evaluated whether lesion‐to‐fat ratio measured by shear wave elastography in patients with Breast Imaging Reporting and Data System (BI‐RADS) 3 or 4 lesions has the potential to further refine the assessment of B‐mode ultrasound alone in breast cancer diagnostics. Methods: This was a secondary analysis of an international diagnostic multicenter trial (NCT02638935). Data from 1288 women with breast lesions categorized as BI‐RADS 3 and 4a–c by conventional B‐mode ultrasound were analyzed, whereby the focus was placed on differentiating lesions categorized as BI‐RADS 3 and BI‐RADS 4a. All women underwent shear wave elastography and histopathologic evaluation functioning as reference standard. Reduction of benign biopsies as well as the number of missed malignancies after reclassification using lesion‐to‐fat ratio measured by shear wave elastography were evaluated. Results: Breast cancer was diagnosed in 368 (28.6%) of 1288 lesions. The assessment with conventional B‐mode ultrasound resulted in 53.8% (495 of 1288) pathologically benign lesions categorized as BI‐RADS 4 and therefore false positives as well as in 1.39% (6 of 431) undetected malignancies categorized as BI‐RADS 3. Additional lesion‐to‐fat ratio in BI‐RADS 4a lesions with a cutoff value of 1.85 resulted in 30.11% biopsies of benign lesions which correspond to a reduction of 44.04% of false positives. Conclusions: Adding lesion‐to‐fat ratio measured by shear wave elastography to conventional B‐mode ultrasound in BI‐RADS 4a breast lesions could help reduce the number of benign biopsies by 44.04%. At the same time, however, 1.98% of malignancies were missed, which would still be in line with American College of Radiology BI‐RADS 3 definition of <2% of undetected malignancies. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
02784297
Volume :
42
Issue :
8
Database :
Complementary Index
Journal :
Journal of Ultrasound in Medicine
Publication Type :
Academic Journal
Accession number :
165046369
Full Text :
https://doi.org/10.1002/jum.16192