Back to Search Start Over

Use of Point-of-Care Ultrasound by Intensive Care Paramedics to Assess Respiratory Distress in the Out-of-Hospital Environment: A Pilot Study.

Authors :
Donovan, Jake K.
Burton, Samuel O.
Jones, Samuel L.
Phillips, Luke M.
Anderson, David
Meadley, Benjamin N.
Source :
Prehospital Emergency Care; 2023, Vol. 27 Issue 6, p800-806, 7p
Publication Year :
2023

Abstract

Respiratory distress is a common presentation attended by paramedics. Chest auscultation has been shown to have low accuracy for diagnosing respiratory complaints, and this can lead to inaccurate patient assessment and potentially poor patient outcomes. Conversely, lung ultrasound is a relatively simple exam allowing for rapid differentiation of respiratory complaints with comparable accuracy to more advanced imaging modalities. Evidence suggests that lung ultrasound is easy to learn and apply and could be ideal for assessment of respiratory illness by paramedics. This study aimed to explore the utility of out-of-hospital lung ultrasound performed by intensive care paramedics (ICP) for patients with medical causes of respiratory distress, and explore whether the use of lung ultrasound affects the ICP's clinical impression or management. This was a prospective observational pilot study. After a training program, a sample of ICPs working in metropolitan and regional Victoria, Australia used ultrasound to assess adult patients with respiratory distress and/or dyspnea. ICPs used a handheld point-of-care ultrasound device to scan respiratory patients using a modified protocol, and completed a worksheet with their scan findings. The scans were then reviewed by a subject matter expert for quality and agreement. Ninety-five patients were enrolled over the study period. The average image quality score was 2.68/5, and 56% of scans were of interpretable quality. Interrater agreement (between the ICPs and the subject matter expert) was reported using Cohen's kappa. Moderate overall agreement (0.44) was shown, with the highest reliability reported in A-profile and B-profile (0.49 and 0.57). In 42% of cases performance of the scan affected paramedic clinical impression and/or management. ICPs can perform lung ultrasound with moderate accuracy for some respiratory conditions, and the scans may affect clinical impression and management. Future research should focus on enhanced education, expert feedback, and clinical outcomes. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10903127
Volume :
27
Issue :
6
Database :
Complementary Index
Journal :
Prehospital Emergency Care
Publication Type :
Academic Journal
Accession number :
169833640
Full Text :
https://doi.org/10.1080/10903127.2022.2107123