Assessment of body composition in pediatric intestinal failure: A comparison study.

Authors :
Yanchis, Dianna
So, Stephanie
Patterson, Catherine
Belza, Christina
Garofalo, Elizabeth
Wong‐Sterling, Sylvia
Silva, Carina
Avitzur, Yaron
Wales, Paul W.
Hulst, Jessie M.
Kong, Dehan
Xuyx, Libai
Courtney‐Martin, Glenda
Source :
JPEN Journal of Parenteral & Enteral Nutrition; Sep2023, Vol. 47 Issue 7, p920-929, 10p
Publication Year :
2023

Abstract

Background: The objective of the study was to compare bioelectrical impedance analysis (BIA) and skinfolds with dual energy x‐ray absorptiometry (DXA) in the assessment of body composition of children with intestinal failure. DXA is the reference method for body composition assessment in clinical settings. Methods: Children aged 1–18 years with intestinal failure whohave DXA as part of routine clinical monitoring were eligible. BIA measured total body water on the same day as DXA. Skinfold measurements were taken at four sites: triceps, biceps, subscapular, and suprailiac. Percentage of fat mass (%FM) and fat‐free mass (%FFM) were derived from resistance and reactance measured by BIA by using age‐specific equations. Percentage of FM was calculated from skinfold measures by using age‐specific equations. Data on patient characteristics, intestinal failure–related factors, and feeding method were collected. Paired t test examined differences in %FM and %FFM and Bland‐Altman analysis determined the agreement between BIA, skinfolds, and DXA. Marginal linear model assessed the effect of age, sex, and feeding method on the difference in body composition obtained between DXA and BIA and between DXA and skinfolds. Results: Sixty‐eight children with intestinal failure, mean age 8.9 ± 4.2 years, were studied. There was no difference between %FFM and %FM obtained by DXA and BIA (P = 0.26), with a mean bias (95% CI) of −0.69 (−1.9 to 0.5) for %FFM. Sex and age were individually and jointly associated with the bias observed between DXA and BIA (P < 0.05). Skinfold and DXA measurements were significantly different (P < 0.05). Conclusions: BIA is an acceptable clinical tool for assessing body composition in pediatric intestinal failure. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01486071
Volume :
47
Issue :
7
Database :
Complementary Index
Journal :
JPEN Journal of Parenteral & Enteral Nutrition
Publication Type :
Academic Journal
Accession number :
171582705
Full Text :
https://doi.org/10.1002/jpen.2540