Back to Search Start Over

Effect of forceful suction and air disinfection machines on aerosol removal.

Authors :
Du, Yaru
Zhao, Fei
Tao, Ran
Liu, Bing
Source :
BMC Oral Health; 9/8/2023, Vol. 23 Issue 1, p1-9, 9p
Publication Year :
2023

Abstract

Backgrounds: Dental procedures involving drilling and grinding can produce a significant amount of suspended aerosol particles (PM) and bioaerosols. This study aims to analyze the size and concentration of aerosol particles generated during drilling and to investigate the effectiveness of two air exchange systems, namely forceful suction (FS) and air disinfection machines (DM), in removing PM. Methods: For this study, 100 extracted permanent teeth were collected and divided into three groups: without suction (n = 50), suction with forceful suction (n = 25), and suction with air disinfection machines (n = 25). The removal rate of suspended aerosol particles was analyzed using particle counters and air data multimeter. Results: When drilling and grinding were performed without vacuum, 0.75% of the aerosol particles generated were PM2.5-10, 78.25% of total suspended aerosol particles (TSP) were PM2.5, and 98.68% of TSP were PM1. The nanoanalyzer measurements revealed that the aerodynamic diameter of most aerosol particles was below 60 nm, with an average particle diameter of 52.61 nm and an average concentration of 2.6*10<superscript>11</superscript> ultrafine aerosol particles. The air change per hour (ACH) was significantly lower in the air disinfection machines group compared to the forceful suction group. Additionally, the number of aerosol particles and mass concentration was significantly lower in the air disinfection machines group compared to the forceful suction group in terms of PM2.5 levels. However, the forceful suction group also reduced the mass concentration in PM10 level than the air disinfection machines group. Conclusion: In conclusion, the air exchange system can reduce the aerosol particles generated during drilling and grinding. Comparing the two air exchange systems, it was found that the air disinfection machines group reduces the number of aerosol particles and mass concentration in PM2.5 levels, while the forceful suction group reduces the mass concentration in PM10 level. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
14726831
Volume :
23
Issue :
1
Database :
Complementary Index
Journal :
BMC Oral Health
Publication Type :
Academic Journal
Accession number :
171844790
Full Text :
https://doi.org/10.1186/s12903-023-03369-1